Installation
1. Installation of indoor, Outdoor unit
1) Selection of the best location
1. Indoor unit
There should not be any heat source or steam
•
near the unit.
• There should not be any obstacles to prevent the
air circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into con-
sideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence or other obstacles.
CAUTION
Install the indoor unit on the wall where the height
from the floor is more than 2.3 meters.
2. Outdoor unit
• If an awning is built over the unit to prevent
direct sunlight or rain exposure, be careful
that heat radiation from the condenser is not
restricted.
• There should not be any animals or plants
which could be affected by hot air dis-
charged.
• Ensure the correct distance is left from the
wall, ceiling, fence, or other obstacles as indi-
cated in the diagram.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
More than
5 cm
More than 10 cm
More than 70 cm
- 21 -
More than 5 cm
More than
5 cm
More than 2.3 m
More than 10 cm