Job Name/Location:
Date:
PO No.:
Architect:
Engr:
Rep:
(Company)
ARNU123TRC2
Multi V™ 4‐Way Ceiling Cassette
12,300
Btu/h Indoor Unit
Performance:
Total Cooling Capacity (Btu/h)
Heating Capacity (Btu/h)
Power Input¹ (kW)
Cooling Nominal Test Conditions:
Indoor:
80°F DB/67°F WB
Outdoor:
95°F DB
Electrical:
Power Supply (V/Hz/Ø)
Rated Amps (A)
Piping:
Refrigerant:
Liquid Line (in, OD):
Vapor Line (in, OD):
Condensate:
Condensate Line (in, OD)
Factory Installed Pump²
Controls Features:
•Auto changeover
  (Heat Recovery Only)
•Auto opera on
•Auto restart
•Child lock
•Dual thermistor control
•Forced opera on
•Group control
•High ceiling
•Hot start
Required Accessories:
Grille Kit (PT‐UQC)
Optional Accessories:
Wireless Handheld Remote Controller ‐ PQWRHDF0
7‐Day Programmable Controller (Black) ‐ PQRCVSL0
7‐Day Programmable Controller (White) ‐ PQRCVSL0QW
Simple Controller with Mode (Black) ‐ PQRCVCL0Q
Simple Controller with Mode (White) ‐ PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) ‐ PQRCHCA0QW
Dry Contact Unit ‐ PQDSB1
Dry Contact Unit ‐ PQDSBC
Wall Mounted Temperature Sensor ‐ PQRSTA0
Ventilation Kit ‐ PTVK430
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lg‐vrf.com
For:
File
Approval
GC:
Mech:
(Project Manager)
12,300
13,600
30
Heating Nominal Test Conditions:
Indoor:
70°F DB
Outdoor:
47°F DB/43°F WB
208‐230/60/1
0.2
1/4 Flare
1/2 Flare
1
Yes
•Self diagnos cs
•Sleep mode
•Timer (on/off)
•Weekly schedule
•So  dry (dehumidifica on)
•Auto direc on/swing (up/down)
•Fan speed control
•Chaos wind (random fan speed)
•Swirl wind (alterna ng vanes)
•Jet cool (fast cooling)
Tag #:
Resubmit
Other
Entering Mixed Air:
Cooling Max³ (°F WB)
Heating Min (°F DB)
Unit Data:
Refrigerant Type
Refrigerant Control
Sound Pressure⁴ dB(A) (H/M/L)
Primary Filter
Secondary Filter
Net Weight (lbs)
Shipping Weight (lbs)
Grille Weight (lbs)
Grille Shipping Weight (lbs)
Fan:
Type
Quantity
Motor/Drive
Airflow Rate H/M/L (CFM)
Standard Features:
•Limited Warranty with LG Cer fied Installa on
     •Two Year Functional Parts Warranty
•Corner Access Panels
Notes:
1.The Power Input is rated at high speed.
2.Maximum li  is 27 in from bo om of unit.
3.See Engineering Manual for sensible and latent capaci es.
4.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
5.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must 
comply with applicable local and national code.
6.Power wiring cable size must comply with the applicable local and na onal code.
7.This unit comes with a dry nitrogen charge.
8.This data is rated 0   above sea level, with 25   of refrigerant line per indoor unit and a 0   
level difference between outdoor and indoor units.  All capacities are net with a combination ratio 
between 95 – 105%.
9.Must follow installa on instruc ons in the applicable LG installa on manual.
R410A
32/30/27
Washable Pre‐filter
Plasma
Turbo
Brushless Digitally Controlled/Direct
307/283/247
VRF‐SB‐DE‐003‐US 012B09
Page 1 of 2
76
59
EEV
32
36
5
8
1

Advertisement

loading

Summary of Contents for LG ARNU123TRC2

  • Page 1 2.Maximum li  is 27 in from bo om of unit. •Hot start •Jet cool (fast cooling) 3.See Engineering Manual for sensible and latent capaci es. 4.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. Required Accessories: 5.All communica on cable to be minimum 18 AWG, 2‐conductor, stranded, shielded and must  Grille Kit (PT‐UQC) comply with applicable local and national code. 6.Power wiring cable size must comply with the applicable local and na onal code. Optional Accessories: 7.This unit comes with a dry nitrogen charge. 8.This data is rated 0   above sea level, with 25   of refrigerant line per indoor unit and a 0    Wireless Handheld Remote Controller ‐ PQWRHDF0 level difference between outdoor and indoor units.  All capacities are net with a combination ratio  between 95 – 105%. 7‐Day Programmable Controller (Black) ‐ PQRCVSL0 9.Must follow installa on instruc ons in the applicable LG installa on manual. 7‐Day Programmable Controller (White) ‐ PQRCVSL0QW Simple Controller with Mode (Black) ‐ PQRCVCL0Q Simple Controller with Mode (White) ‐ PQRCVCL0QW Simple Controller without Mode (Black) PQRCHCA0Q Simple Controller without Mode (White) ‐ PQRCHCA0QW Dry Contact Unit ‐ PQDSB1 Dry Contact Unit ‐ PQDSBC Wall Mounted Temperature Sensor ‐ PQRSTA0 Ventilation Kit ‐ PTVK430 For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg‐vrf.com VRF‐SB‐DE‐003‐US 012B09 Page 1 of 2...
  • Page 2 Job Name/Location: ARNU123TRC2 Tag #: Multi V™ 4‐Way Ceiling Cassette Date: 12,300 Btu/h Indoor Unit PO No.: For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lg‐vrf.com VRF‐SB‐DE‐003‐US 012B09 Page 2 of 2...