Page 2
Multi Multiple type General Information 1.Model Line Up 2.Combination of Indoor and Outdoor Unit 3.Nomenclature...
Page 3
Capacity Index Product Phase Chassis Model Name U18A S32W14ULGA0.EC6BEEU [RM2U15.U18] Multiple type U24A S33W18U2GA0.EC6BEEU [RM3U19.U24] * The capacity index may differ from actual capacity values. Multi Multiple type 2. Combination of Indoor and Outdoor Unit The total capacity index of indoor units is the sum of capacity index of each units and should be within the capacity index of the outdoor unit.
Page 4
Multi Multiple type General Information 3. Nomenclature 3.1 Nomenclature - Outdoor unit Model Name 1. A/C Type Split 2. Refrigerent R410A R290 3. SET : Indoor unit combination number 3 Indoor units 4 Indoor units 4. C/O, H/P and Inverter DC Inverter C/O DC Inverter H/P 5/6.
Page 5
Multi Multiple type General Information 3. Nomenclature 3.2 Nomenclature - Set Model Name 9/10. SET : Sum of Indoor units Capacity 1. A/C Type Indoor unit 1 Indoor unit 2 Indoor unit 3 Code Split 2. Refrigerent R410A R290 3. SET : Indoor unit combination number 3 Indoor units 4 Indoor units 4.
Page 7
Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.1 Specifications Category S32W14ULGA0.EC6BEEU [RM2U15.U18] Unit Major Minor Classification Chassis U18A Case 1 220-230-240, 1, 50 Case 2 Power Supply Limit Range of Voltage(Case 1) 198 ~ 264 Limit Range of Voltage(Case 2) Testing Combination Model x No.
Page 8
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] Category Unit S32W14ULGA0.EC6BEEU [RM2U15.U18] Major Minor Color Warm Gray Exterior RAL (Classic) RAL 7044 High Pressure Prevention Pressure Switch Frost Prevention Thermistor Protection Device Discharge Tempreature Control Thermistor Inverter Protection Thermistor Type Precharged Amount 1.040...
Page 9
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] ■ Performances are based on the following conditions : - Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB - Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB - Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
Page 10
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.2 List of Functions Category Functions Availability Defrost / Deicing High Pressure Switch Low Pressure Switch Reliability Phase Protection Restart Delay (3-minutes) Self Diagnosis Soft Start Night Low Noise Operation Wiring Error Check...
Page 11
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.3 Accessory Compatibility List Category Accessory Name Model Name Description Compatibility AC EZ PQCSZ250S0 AC EZ touch PACEZA000 Touch type AC Smart IV PACS4B000 Touch type AC Smart 5 PACS5A000 Touch type...
Page 12
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.4 Dimensions 1.4.1 Product...
Page 13
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.4.2 Install Space For Side Discharge (capacity < 28.0 kW) [Unit : mm(inch)] ※ Case 1 : No obstacle on top side Obstacle on the Suction side Case 2 : Obstacle on top side...
Page 14
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.5 Piping Diagrams 1.5.1 Normal Outdoor Unit Inlet Air Temperature Thermistor Condensing Temperature Ø6.35 / 2 way Thermistor Flare Connection Electronic Expansion Condenser Out Valve Temperature ROOM A Thermistor ROOM B ROOM A...
Page 16
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.7 Combination Table 1.7.1 Cooling Combination of Total Capacity Input Indoor Unit (kBtu/h Class) UNIT Rated Rated UNIT-A UNIT-B UNIT-C UNIT-D Total Btu/h Btu/h Btu/h 2 UNIT 8,400 14,000 16,100 1,030 1,391 1.7.2 Heating...
Page 17
Product Data Multi Multiple type 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.8 Capacity Tables 1.8.1 Cooling Indoor Air Temp.: ℃WB Combination Outdoor Air Capacity Temp.: ℃DB Index 2.41 0.41 3.13 0.51 3.68 0.59 4.10 0.65 4.52 0.67 4.84 0.67 2.41 0.48 3.13 0.60 3.68...
Page 18
Multi Multiple type Product Data 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.9 Capacity Correction Factor 1.9.1 Cooling Combination Capacity correction factor (%) by equivalent pipe length (m) (Capacity ind ex, kBtu/h) 100.0 100.0 98.0 94.8 91.6 88.4 100.0 100.0 97.6 93.8 89.9 86.1 1.9.2 Heating...
Page 19
Multi Multiple type Product Data 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.10 Operation Limits 1.10.1 Cooling Continuous operation 10 12 Indoor Temperature [°C WB] 1.10.2 Heating Continuous Operation Indoor Tem [°C D B] Note ■ Warming up operation and operative mean that the outdoor unit operates to reach the range of continuous operating, however it may not operate continuously...
Page 20
Multi Multiple type Product Data 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.11 Sound Levels 1.11.1 Pressure Levels Night Low Noise Operation / Silent Mode ■ Cooling SPL [dB(A)] Capacity [%] Mode ▲ Heating Cool Heat Cool Heat Step1 / F1 41.0 43.0 90.0 87.0...
Page 21
Multi Multiple type Product Data 1. S32W14ULGA0.EC6BEEU [RM2U15.U18] 1.11.2 Power Levels Night Low Noise Operation / Silent Mode PWL [dB(A)] Capacity [%] ■ Cooling Mode Cool Heat Cool Heat Step1 / F1 56.0 Step2 / F2 52.0 NR-110 NR-105 *How to set mode can be vary depending on function.
Page 22
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.1 Specifications Category Unit S33W18U2GA0.EC6BEEU [RM3U19.U24] Major Minor Classification Chassis U24A Case 1 220-230-240, 1, 50 Case 2 Power Supply Limit Range of Voltage(Case 1) 198 ~ 264 Limit Range of Voltage(Case 2) Testing Combination Model x No.
Page 23
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] Category Unit S33W18U2GA0.EC6BEEU [RM3U19.U24] Major Minor High Pressure Prevention Pressure Switch Frost Prevention Thermistor Protection Device Discharge Tempreature Control Thermistor Inverter Protection Thermistor Type Precharged Amount 1.400 Additional Charging amount(Main) Additional Charging amount(Branch) Refrigerant GWP(Global Warming Potential)
Page 24
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] ■ Performances are based on the following conditions : - Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB - Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB - Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
Page 25
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.2 List of Functions Category Functions Availability Defrost / Deicing High Pressure Switch Low Pressure Switch Reliability Phase Protection Restart Delay (3-minutes) Self Diagnosis Soft Start Night Low Noise Operation Wiring Error Check Peak Control Convenience Mode Lock...
Page 26
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.3 Accessory Compatibility List Category Accessory Name Model Name Description Compatibility AC EZ PQCSZ250S0 AC EZ touch PACEZA000 Touch type AC Smart IV PACS4B000 Touch type AC Smart 5 PACS5A000 Touch type Central Controller ACP IV PACP4B000...
Page 27
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.4 Dimensions 2.4.1 Product...
Page 28
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.4.2 Install Space For Side Discharge (capacity < 28.0 kW) [Unit : mm(inch)] ※ Case 1 : No obstacle on top side Obstacle on the Suction side Case 2 : Obstacle on top side Front Front Front...
Page 29
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.5 Piping Diagrams 2.5.1 Normal Outdoor Unit Condenser Out Inlet Air Temperature Temperature Thermistor Thermistor Condensing Ø6.35 Temperature Flare Connection Thermistor Electronic Expansion Valve ROOM A Main SVC V/V Field Piping ROOM B Liquid(Ø6.35) ROOM C Pressure...
Page 31
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.7 Combination Table 2.7.1 Cooling Combination of Total Capacity Input Indoor Unit (kBtu/h Class) UNIT Rated Rated UNIT-A UNIT-B UNIT-C UNIT-D Total Btu/h Btu/h Btu/h 2 UNIT 10,800 18,000 21,600 1,400 1,818 3 UNIT 10,800 18,000...
Page 32
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.8 Capacity Tables 2.8.1 Cooling Indoor Air Temp.: ℃WB Outdoor Air Combination Temp.: ℃ Capacity Index 3.10 0.50 4.03 0.63 4.74 0.73 5.28 0.80 5.82 0.83 6.23 0.83 3.10 0.59 4.03 0.74 4.74 0.86 5.28...
Page 33
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.9 Capacity Correction Factor 2.9.1 Cooling Combination Capacity correction factor (%) by equivalent pipe length (m) (Capacity ind ex, kBtu/h) 100.0 100.0 98.0 94.8 91.6 88.4 100.0 100.0 97.6 93.8 89.9 86.1 2.9.2 Heating Combination Capacity correction factor (%) by equivalent pipe length (m)
Page 34
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.10 Operation Limits 2.10.1 Cooling Continuous operation 10 12 Indoor Temperature [°C WB] 2.10.2 Heating Continuous Operation Indoor Tem [°C D B] Note ■ Warming up operation and operative mean that the outdoor unit operates to reach the range of continuous operating, however it may not operate continuously due to safety or protection logic.
Page 35
Multi Multiple type Product Data 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.11 Sound Levels 2.11.1 Pressure Levels Night Low Noise Operation / Silent Mode ■ Cooling SPL [dB(A)] Capacity [%] Mode ▲ Heating Cool Heat Cool Heat Step1 / F1 43.0 46.0 95.0 88.0 Step2 / F2 39.0...
Page 36
Product Data Multi Multiple type 2. S33W18U2GA0.EC6BEEU [RM3U19.U24] 2.11.2 Power Levels Night Low Noise Operation / Silent Mode PWL [dB(A)] Capacity [%] ■ Cooling Mode Cool Heat Cool Heat Step1 / F1 57.0 Step2 / F2 53.0 NR-110 NR-105 *How to set mode can be vary depending on function. Please refer to manual for details.
Page 37
Installation Installation of Outdoor Unit...
Page 38
Installation of Outdoor Unit Installation 1. Information for Refrigerant 1.1 Alternative Refrigerant The type of refrigerant applied depends on the outdoor unit cycle configuration. Ensure the refrigerant type in the specification of the indoor unit and outdoor unit to be installed. ■...
Page 39
Installation of Outdoor Unit Installation 1. Information for Refrigerant 1.2 Minimum Floor Area for Installation : accordance with IEC05 Floor location Wall mounted Ceiling mounted Total refrigerant amount in the system ( kg ) <!> CAUTIONS • "Minimum Area for installation" might be different by revision of IEC regulation. "Minimum Area for installation" should be selected in accordance with that revision based on the local and national environment.
Page 40
Installation of Outdoor Unit Installation 1. Information for Refrigerant 1.3 Minimum Floor Area for Installation : accordance with IEC06 2500 Floor standing 2000 1500 1000 Wall mounted Ceiling mounted Total refrigerant amount in the system ( kg ) <!> CAUTIONS •...
Page 41
Installation of Outdoor Unit Installation 2. Selection of the best Location 2.1 Best Location Select space for installing outdoor unit, which will meet the following conditions: • No direct thermal radiation from other heat sources. • No possibility of annoying neighbors due to noise of unit. •...
Page 42
Installation of Outdoor Unit Installation 2. Selection of the best Location 2.2 Special guide for installation at the Seaside Windbreak Sea wind Sea wind Sea wind ※ This figure is representative. Actual appearance of outdoor unit may be different by product type. <...
Page 43
Installation of Outdoor Unit Installation 3. Refrigerant Piping System • This figure is representative. Actual appearance of units may be different by product type, but schematic diagram will stay the same. • Specific design limit details may differ depending on each model. Refer to the ‘Specifications’ and ‘Combination Table’. (Maximum piping length, elevation height, combinable number/capacity of indoor unit, type of combinable indoor unit type, etc) •...
Page 44
Installation of Outdoor Unit Installation 4. Electrical Wiring • The conductive shielding layer of cable should be grounded to the metal part of both units. • As this unit is equipped with an inverter, to install a phase leading capacitor not only will deteriorate power factor improvement effect, but also may cause capacitor abnormal heating.
Page 45
Installation of Outdoor Unit Installation 5. Field Wiring !! This System is representative Example. !! * : Actual combination of indoor units and BD units may be different by Product line-up of region or Product Type. Outdoor Power Supply (Main Switch) R S T N R S T Switch...
Page 46
Copyright 2023 LG Electronics Inc. All Rights Reserved. The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system. The specifications, designs, and information in this brochure are subject to change without notice.