Functions
Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
ƒURoom temperature sensor. (Thermistor)
Room temperature control
ƒUMaintains the room temperature in accordance with the Setting Temp.
Starting Current Control
ƒUIndoor fan is delayed for 5 seconds at the starting.
Time Delay Safety Control
ƒURestarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
ƒUHigh, Med, Low
Soft Dry Operation Mode
ƒUIntermittent operation of fan at low speed.
Auto Operation
ƒUThe setting temperature, indoor fan speed and desired operation mode are automatically set.
Deice (defrost) control (Heating)
ƒUBoth the indoor and outdoor fan stops during defrosting.
ƒUHot start after defrost ends.
Hot-start Control (Heating)
ƒUThe indoor fan stops until the evaporator piping temperature will be reached at 28°C.