6. Connecting Cables between Indoor Unit and Outdoor Unit
1) Connecting cables to the Indoor Unit
1) Remove the Air guide - L by loosening 2 screws
after removing the Inlet grille from the Indoor
unit.
2) Connect the wires to the terminals on the con-
trol board individually according to the outdoor
unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively
2) Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly.
For the heat pump model, put the 0.75mm
er boss of the control panel.
4) In Australia, the length of power supply cord measured from the entry of the power supply cord to the middle of live pin on
the power plug should be over 1.8m.
The power cord connected to the outdoor unit
should be complied with the following specifications
(Type H05VV-F(Indoor) approved by HAR or SAA).
cable(thinner cable) on the clamp and tighten it with a plastic clamp to the oth-
2
CAUTION
NORMAL CROSS-
SECTIONAL AREA
2
• 3.5mm
–28–
AIR GUIDE-L
INDOOR UNIT
1
Clamp
The connecting cable connected between
the indoor and outdoor unit should be complied
with the following specifications
(Type H07RN-F approved by HAR or SAA).
2
Control
Panel
NORMAL CROSS-
SECTIONAL AREA
2
0.75mm