6. Natural wind by CHAOS logic
Intake Air temp.
Cooling on temp.
(Setting temp.+0.5)
Setting temp.
Cooling off temp.
(Setting temp.-0.5)
INDOOR FAN
OUTDOOR FAN/COMP.
: Setting fan speed
7. Soft Dry Operation
• During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1°C, the compressor OFF
temperature is the setting temperature minus 0.5°C.
• When the room temperature rises over the compressor ON temperature, the operation mode is switched to the cool-
ing mode.
• When the room temperature falls between the compressor ON temperature and OFF temperature, the operation
mode is switched to the Soft Dry Operation.
In this temperature range, 10min. Dry Operation, 7min operation OFF. During 10min Dry operation, if the room tem-
perature falls below compressor OFF temperature, Compressor OFF.
• In micom dehumidify mode, control of fan speed is as following.
Intake Air temp.
Setting temp. +1.0˚C
(Compressor ON)
Setting temp.
Setting temp. -0.5˚C
(Compressor OFF)
COMPRESSOR
OUTDOOR FAN
INDOOR FAN
Setting CHAOS Natural wind
: CHAOS Natural wind
GRAPH of Natural wind by the CHAOS logis (During Cooling operation)
Cooling
2min.58sec.
10min.
ON
OFF
ON
ON
OFF
ON
Selected
Fan
For more fresh feeling than other fan speed mode, press
the indoor fan Speed Selector and set to CHAOS mode.
In this mode, the wind blows like natural breeze by auto-
matically changing fan speed according to the CHAOS
logic.
: LOW
: COMP ON
7min.
10min.
Within 7min. Cooling
OFF
ON
OFF
OFF
ON
OFF
Low Fan
–13–
: COMP OFF
2min.58sec.
ON
OFF
ON
ON
OFF
ON
Selected
Low Fan
Fan
OFF
OFF