• Auto Operation for Cooling. (Cooling only Model)
Operation Condition
When Auto Operation
initial start
When pressing room temp-
erature setting button
during Auto Operation
Intake-Air temp
Setting Temp. +0.5°C
(Compressor OFF)
Setting Temp.-0.5°C
(Compressor ON)
Indoor Fan
Compressor
• Auto Operation for Soft Dry
The Setting temperature will be same as that of the current intake-air temperature.
- Compressor ON temperature; Setting temperature +1°C
- Compressor OFF temperature; Setting temperature -0.5°C
• 1/f rhythm louver operation : In Auto operation mode, when pressing the vertical air direction control button, lou-
ver moves as following cycle.
MODE0
MODE1
MODE2
MODE3
MODE4
Intake-air Temperature
Over 26°C
Over 24°C~below 26°C
Over 22°C~below 24°C
Over 20°C~below 22°C intake air temperture
below 20°C
Over 20°C~below 30°C
below 20°C
over 30°C
ON
End
MODE5
MODE6
Setting temperature
25°C
Intake air -1°C
Intake air -0.5°C
20°C
by Fuzzy logic
Fuzzy control
20°C
30°C
Fuzzy Speed
OFF
Start
–12–
Fan speed
Air Direction Control
In this mode, when
pressing the verti-
cal air diretion con-
Controlled
trol.
Button, louvers
moves to 1/f
rhythm (refer to
page 17)
ON
OFF
MODE9
(CLOSED)