Summary of Contents for ABB L240

  • Page 1 Security Technology Software WIN-PC for Intrusion Alarm Panel L240 Product Manual...
  • Page 3: Table Of Contents

    2.1 Login ..........3 Connection points to the panel L240 ..... .
  • Page 4: General Description

    The connection of the panel and the PC is implemented either via the Interface Module L208/V24, where a free V24 interface (COM port) or a connection to the LAN network is required. The IP Interface L240/IP is required for this purpose.
  • Page 5 Software WIN-PC for Intrusion Alarm Panel L240 After successful login the WIN-PC user interface starts. WIN-PC program window...
  • Page 6: Connection Points To The Panel L240

    Software WIN-PC for Intrusion Alarm Panel L240 Connection points The connection of the L240 to the PC is implemented either via a serial interface with the Interface Module L208/V.24 or via a LAN network with to the panel L240 the IP Interface L240/IP.
  • Page 7: Setting The Interface Parameters

    Panel by fast flashing. • After commissioning, remove jumper LK1 and close the enclosure cover. Note: Only one Interface Module L208/V.24 or L240/IP can be operated on the panel at any time. 3.2.1 Setting the interface In order to establish the connection between the panel and the PC, some...
  • Page 8: Lan/Ethernet Connection With L240/Ip

    PC. A normal patch cable is required to connect via a router or switch. • On the IP Module L240/IP, set DIP switch 1 to “ON”, DIP switches 2-8 must be set to “OFF”. • Connect IP module (terminal CN1 XIB) during operation to the XIB security bus.
  • Page 9: Setting The Ip Address On The Pc

    • After commissioning, remove jumpers LK1 and LK2 and close the enclosure cover. Note: Only one Interface Module L208/V.24 or L240/IP can be operated on the panel at any time. 3.3.1 Setting the IP address The Interface Module L240/IP requires a fixed IP address setting for ope- on the PC ration.
  • Page 10: Setting The Network Parameters On The L240

    Software WIN-PC for Intrusion Alarm Panel L240 What is an IP address? An IP address is used in computer networks, for example the Internet, to transport data from the transmitting party to any intended recipient. Similar to a postal address on an envelope, the data packages are provided with an IP address which uniquely identifies the recipient.
  • Page 11 Software WIN-PC for Intrusion Alarm Panel L240 • In Submenu “05=Panel-IP” the IP address of the network module L240/IP is entered. The point between the numbers can be achieved by pressing the arrow key “ ”. Panel IP 192.168.3.3 Entry of the L240/IP IP address Acknowledge the IP address with the “Return”...
  • Page 12: First Steps In Win-Pc

    First steps in WIN-PC WIN-PC is used to read out and manage the configuration data of the Intrusion Alarm Panel L240. In order to guarantee that the system para- meters correspond with the data in WIN-PC, the bus device connected to the panel must be set on the central control panel.
  • Page 13: Selection Of Connection Type

    Intrusion Alarm Panel (see figure). Acknowledge the settings with “OK”. IP (LAN/Ethernet) Select the option IP in field “Primary Route”. The IP number of the L240/IP is entered in the field “Primary Number”. 4.1.2 Configuration file The configuration file required for saving the customer configuration is created by pressing button “...
  • Page 14: Connection To The Panel

    Connection to the panel After the customer account is created, a connection with the Intrusion Alarm Panel L240 can be established. For this purpose, go to the “Panel Connection” in the customer tree and then click on the “Connect” button in the main window. After a connection is established, the following message is shown: “Connected to Panel: Please select an...
  • Page 15 Software WIN-PC for Intrusion Alarm Panel L240 In order to close the connection press button “Disconnect” in the “Panel Connection” window.
  • Page 16: Configuration

    Software WIN-PC for Intrusion Alarm Panel L240 Configuration In the customer tree, the existing customer and configuration menus are represented as a tree structure. The tree is expanded or reduced by clicking on the “+/-” symbols. The areas of Configuration, Event Log, Access Log and Panel Connection are available for selection.
  • Page 17: Configuration

    Here too, the date of the last configuration change and the WIN-PC version (GSR Editor Version) are displayed. The configuration options for the Intrusion Alarm Panel L240 can be seen by opening the configuration tree. (Click on the “+” symbol).
  • Page 18 Software WIN-PC for Intrusion Alarm Panel L240 Accepting/comparing configuration Migrate configuration Compare configuration After changing the panel firmware, it is necessary to adapt the configuration data to the new firmware. A further window will open after pressing “Migrate Config”. In the example figure, the customer file of GSR ID “1234”...
  • Page 19: Configuration Tree

    Intrusion Alarm Panel L240. The individual points for configuration of the L240 are described in detail in the manual of the Intrusion Alarm Panel in chapter “Configuration and programming by the commissioning engineer”.
  • Page 20: Circuits

    “Cct Type” field. The selection corresponds with the Engineering edit menu “03=Circuits” on the Intrusion Alarm Panel L240. The text “ON” is bold for emphasis. 5.4.3 Print/Copy The entries made on the configuration page can be printed out as an overview using the “Print”...