Download Print this page

Advertisement

Quick Links

R R o o u u n n d d B B o o i i l l i i n n g g P P a a n n s s
N7E
E E N N
Installation and operating manual *
59589F501- 2018.09
*Original instructions

Advertisement

loading

Summary of Contents for Electrolux N7E

  • Page 1 R R o o u u n n d d B B o o i i l l i i n n g g P P a a n n s s E E N N Installation and operating manual * 59589F501- 2018.09 *Original instructions...
  • Page 2 F F o o r r e e w w o o r r d d The installation, use and maintenance manual (hereinafter Manual) provides the user with information necessary for correct and safe use of the machine (hereinafter “machine“ or “appliance“). The following must not be considered a long and exacting list of warnings, but rather a set of instructions suitable for improving machine performance in every respect and, above all, preventing injury to persons and animals and damage to property due to im- proper operating procedures.
  • Page 3 Machine disposal........................12 B TECHNICAL DATA ..........................12 Dataplate position........................12 Appliance and manufacturer's identification data ................12 N7E Gas/electric appliance technical data ..................13 C GENERAL INFORMATION ........................13 Law requirements only for Australia ....................13 Introduction ..........................13 Intended use and restrictions ......................
  • Page 4 Pressure switch (indirect versions only) ................... 20 Round boiling pan use — Gas models..................... 20 F.5.1 Lightning on ........................20 F.5.2 Pressure switch ........................ 20 F.5.3 Switching off ........................20 Round boiling pan use — Electric Models ..................21 F.6.1 Switching Off........................21 F.6.2 Cooking ..........................
  • Page 5 W W A A R R N N I I N N G G A A N N D D S S A A F F E E T T Y Y I I N N F F O O R R M M A A T T I I O O N N A A .
  • Page 6: Normal Use

    A A . . 2 2 P P e e r r s s o o n n a a l l p p r r o o t t e e c c t t i i o o n n e e q q u u i i p p m m e e n n t t S S u u m m m m a a r r y y t t a a b b l l e e o o f f t t h h e e P P e e r r s s o o n n a a l l P P r r o o t t e e c c t t i i o o n n E E q q u u i i p p m m e e n n t t ( ( P P P P E E ) ) t t o o b b e e u u s s e e d d d d u u r r i i n n g g t t h h e e v v a a r r i i o o u u s s s s t t a a g g e e s s o o f f t t h h e e m m a a c c h h i i n n e e ' ' s s s s e e r r v v i i c c e e l l i i f f e e .
  • Page 7: Residual Risks

    • Place emergency telephone numbers in a visible position. • The A-weighted emission sound pressure level does not exceed 70 dB(A). • Turn the appliance off in case of fault or poor operation. • Do not use products (even if diluted) containing chlorine (sodium hypochlorite, hydrochloric or muriatic acid, etc.) to clean the appliance or the floor under it.
  • Page 8: Mechanical Safety Characteristics, Hazards

    To preserve these conditions, the areas around the machine must always be: – kept free of obstacles (e.g. ladders, tools, containers, boxes, etc.); – clean and dry; – well lit. For the Customer's complete information, the residual risks remaining on the machine are indicated below: such situations are deemed improper and therefore strictly forbidden.
  • Page 9 load to fall off the vehicle. Before unloading the machine components, make sure all the anchoring systems are removed. • Machine positioning, installation and disassembly must be carried out by specialised personnel. A A . . 6 6 I I n n s s t t a a l l l l a a t t i i o o n n a a n n d d a a s s s s e e m m b b l l y y •...
  • Page 10 A A . . 1 1 0 0 P P o o s s i i t t i i o o n n i i n n g g • Install the appliance, taking all the safety precautions required for this type of operation, also respecting the relevant fire-prevention measures.
  • Page 11: Ordinary Maintenance

    • placing in the machine any objects or things not compatible with its use, or that can damage the machine, cause injury or pollute the environment; • climbing on the machine; • non-compliance with the requirements for correct machine use; •...
  • Page 12 A A . . 1 1 3 3 S S e e r r v v i i c c e e • Only original spare parts can ensure the safety standards of the appliance. A A . . 1 1 4 4 M M a a c c h h i i n n e e d d i i s s p p o o s s a a l l •...
  • Page 13 IMQ/GS gas category gas pressure Pmbar Electrolux Professional SpA Viale Treviso 15 33170 Porde- manufacturer none Italy B B . . 3 3 N N 7 7 E E G G a a s s / / e e l l e e c c t t r r i i c c a a p p p p l l i i a a n n c c e e t t e e c c h h n n i i c c a a l l d d a a t t a a...
  • Page 14 Protection safety measures consisting of the use of Electrolux Professional SpA declines any liability for inaccur- devices specific technical means (guards and acies contained in the manual, if due to printing or translation safety devices) for protecting operators errors.
  • Page 15 I I N N S S T T A A L L L L A A T T I I O O N N A A N N D D A A S S S S E E M M B B L L Y Y W W A A R R N N I I N N G G 4.
  • Page 16 • See the installation diagram for the type and position of c. screw it tightly onto the bottom connection. appliance connections. E E . . 6 6 G G a a s s C C o o n n n n e e c c t t i i o o n n s s E E .
  • Page 17 E E . . 7 7 G G a a s s a a p p p p l l i i a a n n c c e e s s r r e e g g u u l l a a t t i i o o n n s s E E .
  • Page 18 8. Prior to operation, test the gas pressure regulator for leaks. 2. Remove the appliance front panel; 3. Connect the power cable to the terminal block according to the wiring diagram provided with the appliance; 4. Secure the power cable with the cable clamp “E“. I I M M P P O O R R T T A A N N T T The manufacturer declines any liability if the safety regulations are not respected.
  • Page 19 E E . . 1 1 1 1 . . 1 1 A A u u t t o o m m a a t t i i c c f f i i l l l l i i n n g g p p a a n n s s E E .
  • Page 20 NOTE! F F . . 2 2 W W a a t t e e r r f f i i l l l l i i n n g g At the start of every day and with the appliance cold, check that the cavity water level is not below minimum: •...
  • Page 21 F F . . 6 6 R R o o u u n n d d b b o o i i l l i i n n g g p p a a n n u u s s e e — — E E l l e e c c t t r r i i c c M M o o d d e e l l s s F F .
  • Page 22 Boilers or cavities (every 3–4 months) • Go over all stainless steel surfaces vigorously with a cloth moistened with paraffin oil in order to create a protective • Descale the devices used for holding and heating of water film; (e. g. cavities of indirect pans) by filling them with pure •...
  • Page 23 R R e e p p a a i i r r a a n n d d e e x x t t r r a a o o r r d d i i n n a a r r y y m m a a i i n n t t e e n n a a n n c c e e • Electrolux - Tom Stoddart Pty Ltd — 39 Forest Way, Karawatha QLD 4117 —...
  • Page 24 any case, the current environmental protection laws in the compressor contains lubricant oil and refrigerant fluid which user's country must be observed. can be recycled, and that the refrigerator components are special waste assimilable with urban waste. H H . . 2 2 P P r r o o c c e e d d u u r r e e r r e e g g a a r r d d i i n n g g a a p p p p l l i i a a n n c c e e d d i i s s m m a a n n t t l l i i n n g g The symbol on the product indicates that this m m a a c c r r o o o o p p e e r r a a t t i i o o n n s s...
  • Page 26 Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www.electrolux.com/professional...