hit counter script

LG A2UW18GFA0 Svc Manual page 53

Multi air conditioner
Hide thumbs Also See for A2UW18GFA0:
Table of Contents

Advertisement

Part 5. Trouble Shooting
Display
Title
code
Drain pump
04
/ Float switch
CN Float
0
Ω"
Ω"
Check the resistance
Check Point
1. Check the wire connection. (Open, Soldered poorly) → Repair the connection or change the PCB.
2. Check the resistance of float switch (Abnormal : Open, Normal : short) → Check the float switch.
3. Check the level of water
4. Check the volt. Of Drain pump power supply. (AC 230V) → Repair or Change the main PCB.
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Cause of error
• Float switch Open.
(Normal : short)
CN-Float
- 52 -
Check point & Normal condition
• The connection of wire(Drain pump/ Float switch)
• Drain pump power input. (230V)
• Drain tube installation.
• Indoor unit installation. (Inclination)
CN-D/PUMP
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A3uw24gfa0Ldn127hv4

Table of Contents

Uploaded: cache9/manual/2713673/Lg-A2uw18gfa0.html%3Fpage%3D53.gz