Fixing Installation Plate
The wall you select should be strong and
solid enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline.
It is also important to use caution
concerning the location of the installation
plate-routing of the wiring to power outlets
is through the walls typically. Drilling the
hole through the wall for piping connections
must be done safely.
Installation plate
Ø70
90
<Type 1>
Left rear piping
Ø70
133
<Type 2>
Left rear piping
Place a level on raised tab
Unit Outline
442
Ø70
Left
Installation Plate
rear
piping
133
175
<Type 3>
Indoor Type
Wall mounted
ART COOL Mirror
Right rear piping
Installation plate
Right rear piping
442
95
217
Capacity (kBtu/h)
9,12
18,24
9,12
18,24
Chassis
<Type 1>
Chassis
<Type 2>
Ø70
<Type 3>
70
Ø70
100
<Type 4>
Unit Outline
Ø70
Ø70
Right
rear
Left
piping
rear
69
piping
105
Installation of Indoor, Outdoor Unit
Installation Plate
Hook
Type "A"
Installation Plate
Hook
Type "A"
Installation Plate
Chassis
Hook
Installation Plate
Chassis
Hook
Place a level on raised tab
460
Installation Plate
Measuring Tape
Measuring Tape
Hanger
<Type 4>
Type
3
4
1
2
Installation Manual 7
Type "A" Screws
Type "A" Screws
570
Ø70
Right
rear
56
piping
207
(Unit : mm)