Download Print this page
Haier YR-E20 Operation & Installation Manual

Haier YR-E20 Operation & Installation Manual

Wired controller

Advertisement

Quick Links

Wired Controller
Operation & Installation Manual
YR-E20
CONTENT
Wired Controller Instruction ................................................ 1
Wired Controller Function .................................................. 7
Wired Controller Wiring Connection ................................. 35
• Please read this operation manual before using the air conditioner.
• Please keep this manual carefully and safely.

Advertisement

loading

Summary of Contents for Haier YR-E20

  • Page 1 Wired Controller Operation & Installation Manual YR-E20 CONTENT Wired Controller Instruction ..........1 Wired Controller Function ..........7 Wired Controller Wiring Connection ......... 35 • Please read this operation manual before using the air conditioner. • Please keep this manual carefully and safely.
  • Page 2 Wired Controller Instruction Interface Display...
  • Page 3 Keys ON/OFF key Temperature increase/decrease key, it can be used for the time adjustment of clock, timer and sleeping time, energy saving parameter adjustment, temp. compensation parameter adjustment, selecting function, and energy saving setting with fan speed key. The adjustment step is 0.5°C. If energy saving mode is not set,the temperature setting range is from 16°C to 30°C.
  • Page 4 Mode key, press this key, the mode is shown in cycle [intelligent]-[cooling]-[heating]-[fan]-[dry]- [intelligent] Note: No heating mode for cooling only unit or if communication is abnormal. Fan speed key, press this key to adjust fan speed. Function key, it is used for clock setting, timer, swing, fresh, health, electrical heating, sleeping, energy saving, turbo, quiet function, etc.
  • Page 5 Icon Instruction Clock Present/history error code inquiry, Energy saving data display. Timer on, Timer off, Timer on/off. Temperature display, the accuracy is 0.5°C. For example, 25.0°C will be displayed if the temperature is an integer. It is used for temperature compensation data display, sleeping time display.
  • Page 6 Filter cleaning Fresh, this icon is displayed if fresh is set; no fresh is displayed if it is not set. Electrical heating Health Sleeping, this icon is displayed after sleeping is set. The sleeping time is displayed when the function cycle shift to sleeping.
  • Page 7 dFg (Only valid for part of models) Child lock, this icon is displayed only after you set child lock, or it will not display. Intelligent mode Cooling mode Heating mode Fan mode Dry mode...
  • Page 8 Wired Controller Function Dip Switch Instruction Default switch Inverter unit On/Off unit Ambient temperature Ambient temperature display no display Room temperature Room temperature sensor on PCB is sensor on wired valid controller is valid Function cycle Function cycle (simple version) (general version) Old Protocol Selfadaption...
  • Page 9 Setting for Special Function Pressing function key in 5 seconds Function setting continuously Set the non-volatile memory after the On (unit is on)+ buzzer sounds 4 times pressing function Cancel the non-volatile memory after the key 10 times buzzer sounds 2 times 1.
  • Page 10 Pressing function key in 5 Function setting seconds continuously Unit is on+ heating mode After the buzzer sounds 3 +30°C + high speed+ function times, wired controller send 6 times (30°C changes to be the “forced defrost” to indoor the limit highest temperature if unit, the defrost icon flashes 3 energy saving is set) times, then disappears.
  • Page 11 Screen Saving 1. In the state of off and non screen saving, keep pressing for 5s to set screen saving time, which will be shown after the top-left colon 88 statically. Press up/down key to adjust screen saving time and press function key to confirm. 2.
  • Page 12 7. Under Off state, the clock, ambient temperature (if SW2 is ON) , timer (if you set) and fresh (only in the case of setting fresh when wired controller is off) is displayed ,you can set clock, timer, fresh, child lock,temperature compensation paremeter,ambient temperature display under Off state.
  • Page 13 Timer 1. Timer mode: timer on, timer off, timer on/off. 2. Time precision: 1 minute/1 hour; Timer clock is based on the current clock time, when timer clock is over, the timer icon disappears and execute the timer function. 3. Timer & on/off: timer can be set whenever unit is on/off. The controller show the timer icon and time whenever the unit is on/off if you set the timer.
  • Page 14 ② When setting timer off, default 12:00PM (previous setting will be displayed if there is setting before) “ON” and timer on hour place will flash. Press fan speed key to shift to “ON” and minute place of timer on. Press fan speed key again to shift to “OFF”...
  • Page 15 flashing; Press fan speed key again, then the hour and “OFF” are flashing. Press up/down key to adjust the time, minus/add 1 hour a time. Keep pressing to accelerate the adjusting speed; Press fan speed key again, the minute position and “OFF” are flashing. The controller will judge the order of timer on and off and use the arrow show the order.
  • Page 16 ⑥ Requirement of timer setting: When the setting time is the same with current time or timer on is the same with timer off ,it cannot be confirmed by function key but remain the current state, buzzer buzzing normally; If there is no changing operation and no key pressing for 10 seconds, it will quit setting and setting invalid.
  • Page 17 2. 7 fan speeds Press , fan speed is changed in cycle: seventh fan speed → sixth fan speed → fifth fan speed → fourth fan speed → third fan speed → second fan speed → first fan speed → AUTO →...
  • Page 18 3. For part of models, the angle of Up/Down swing can be adjusted: Press function key to enter function circulation, the Up/ Down swing icon will flash, then press the function key again, the angle of the Up/Down swing will flash (if powered on for the first time, the default angle will be different according to different modes;...
  • Page 19 The swing function exit: Pressing Fan key or Mode key can both exit swing function; After adjusting angle of swing, press function key to confirm the angle and exit the swing function; In the adjustment process, if there is no key pressed for 10s, swing function will be exited, and swing angle will execute the final adjusted angle.
  • Page 20 Electrical Heating 1. Set or cancel by function and up/down keys. You can find the electrical heating under heating mode or intelligent mode heating running only. 2. The electrical heating is switched on automatically if SW8 is OFF, the electrical heating icon displays. You can cancel this function manually after it is switch on automatically, then when wired controller is switched on again with heating mode or changing to heating mode again, electrical...
  • Page 21 Health 1. Press function key and up/down key to shift to and it flashes, and then press function key again to confirm the setting. If health is set, execute the above operation to cancel the health. 2. The health function will be kept once the wired controller is switched on again and mode changing when it has been set.
  • Page 22 Turbo/Quiet 1. Choose the by function and up/down keys, when the icon flashes, press function again to set or cancel the quiet function. The turbo function operation is same to quiet function. 2. After setting turbo/quiet, fan speed changes to auto. Under this state, you will quit turbo/quiet function if you press fan speed key and the fan speed will return to the state before entering into turbo/quiet.
  • Page 23 3.This function is valid only when SW4 is OFF and invalid when SW4 is ON. Switch between Fahrenheit and Celsius 1. If the current temperature is displayed in Celsius, set temp. should be adjusted to 30°C in each mode(when energy saving function is set currently, the heating mode will be the highest limit value of the energy saving function).
  • Page 24 Self-cleaning function 1. How to set: (1) Press function key to enter function setting, then press up/down key till CL icon flashing, press function key again, self-cleaning function is successfully set,“CL”icon stop flashing. (2) There is remote control receiver in wired controller, self- cleaning function can also be set by remote controller.
  • Page 25 Special Functions For part of models, if indoor unit is responded as four-way cassette, press function key for 5 seconds to enter function circulation, press Up/Down key to shift to motion sensing A, motion sensing B, motion sensing. 1. Motion sensing: Press function key for 5 seconds to enter function circulation and then press up/down key to shift to motion sensing A (the second 8 digit of 88.8 of temp.
  • Page 26 (5) This function is valid in function circulation only when the indoor unit is responded as four-way cassette. (6) Four-way cassette or health airflow function is invalid when motion sensing is set,then setting four-way cassette or health airflow function again, motion sensing becomes invalid and motion sensing icon disappears.
  • Page 27 (2) After powering on, press function key to shift swing blade and the following circulation: four-way simultaneous control→four-way cassette1→four-way cassette2→four- way cassette3→four-way cassette4→four-way cassette simultaneous control. If it is not the initial entering, press function key to display the last swing blade position and flashing, and it will display the last setting swing angle of this swing blade on the right-side up/down swing.
  • Page 28 (4) The initial entering default position after powering on is as above mentioned, and the swing angle will in circulation by up/down key from default position, for example, if current position is in position 3, press up key to position 2, press down key to position 4. If it is not initial entering, swing angle will in circulation from the last setting angle.
  • Page 29 ECO Parameter Setting 1. Unit on+cooling+30°C, keep pressing fan+ up keys for 5 seconds, ECO parameter is displayed on top-left corner, and the setting icon statically displays 23°C is the default data in cooling mode. This is to say, the target cooling temperature is from 23°C to 30°C.
  • Page 30 2. Keep pressing function key for 5seconds (if indoor unit is responded as four-way cassette, keep pressing function key for 10 seconds, the controller will display error.), the controller will display error. Current error will be displayed before colon at top-left corner and historic error after the colon.
  • Page 31 2. Keep pressing fan speed key and function keys for 5s together to set or cancel child lock, this setting way can execute the same function to the other way that pressing function key 12 times or 4 times in 5s to set or cancel child lock.
  • Page 32 2. Wired controller runs as no non-volatile memory function if the EEPROM is broken, even if you set the non-volatile memory function. 3. No matter non-volatile memory is valid or invalid,error code,ECO parameter and temperature compensation will be remembered. Temperature Compensation 1.
  • Page 33 Rated Cooling Under on state, cooling, high speed, 16°C (if energy saving mode is set, it is the limit lowest temperature), and press function key 8 times in 5 seconds to enter rated cooling mode after the buzzer sounds 5 times, the state is high speed and standard cooling swing.
  • Page 34 2. The wired controller will always show ambient temperature when SW2 is ON. Forced Defrost Under heating, high speed, 30°C (or the limit highest temperature in ECO mode), press function key 6 times in 5 seconds. The buzzer will sound 3 times. The wired controller send the forced defrost signal to indoor unit.
  • Page 35 Display the parameters of air quality (Used for parts of models) 1. If the indoor which wired controller connects has the air quality function, the clock area shows the parameters of air quality. 2. The parameters show as follow: Parameters Screen shows PM2.5 P+digital...
  • Page 36 Wired Controller Wiring Connection 1. Pull the communication wire though the hole of back cover. press this clip to open the wired base box back cover...
  • Page 37 2. Fix the back cover to base box. Then connect the communication wire to wired controller. Put the front board of wired controller to back cover. Finish the installation. Please connect the red terminal of communication wire to indoor unit PCB. There is a shielded wire at the red terminal part, which should be linked to indoor unit ground wire.
  • Page 39 线控器 使用安装说明书 YR-E20 目录 线控器说明�����������������������������������������������������������������������1 线控器功能说明����������������������������������������������������������������5 线控器接线说明��������������������������������������������������������������27 • 使用前请仔细阅读本说明书 • 阅后请妥善保存 • 售后服务热线:4006 999 999...
  • Page 40 线控器说明 界面显示...
  • Page 41 按键显示 开关键。 温度加 / 减键,同时用于时钟、定时与睡眠的时间调 整,节能参数调整,温度补偿参数调整,功能选定, 以及分别与风速键组合设定节能参数。温度调整单 位为 0.5℃。若未设置节能功能,温度调整上下限为 16℃到 30℃;若设置节能功能,则制冷 / 除湿模式 时温度调节下限和制热模式时温度调节上限以节能 参数的设置为准,出厂默认制冷 / 除湿模式 23℃, 制热模式 26℃。 注:若当前拨码 SW2 为 ON,即显示环温,则关 机状态下,温度区显示环温;从关机→开机、切换 模式、调整设定温度等情况时,会静态显示设定温 度 3 秒钟,3 秒后静态显示环温。 模式调整键,按此按键,模式按照【智能】→【制冷】 → 【制热】 → 【送风】 → 【除湿】 → 【智能】 循环切换。 注:单冷机型或者通讯异常时无制热模式。...
  • Page 42 图标说明 时钟 当前 / 历史故障查看,节能参数显示。 定时开、定时关、定时开 / 关。 温度显示区,精确到 0.5℃,若为整数,则 显示如 25.0℃,温度补偿参数显示,睡眠 时间显示 . 当线控器设置显示环温时,左上 角的温度计图标会跟随显示。 设置,设置节能参数、温度补偿参数的同时 显示设置图标。 故障,当出现通讯故障以及室内机故障时, 显示此图标,故障消除后,图标消失。 摆风图标,若有摆风,此图标动态显示;未 设置摆风功能,此图标无。 滤网清洗标志 新风,当设置新风功能时,显示此图标;未 设置新风功能,此图标无。 电加热 健康...
  • Page 43 睡眠 ,若设置睡眠,显示此图标,当再次功能设定循 环到睡眠时,温度区域显示已设定的睡眠时间。 节能 安静 强力,睡眠设定后,不能设定强力功能;强力功能设 定后,再设置睡眠功能,强力功能取消。 锁定,当通讯传递锁定命令时,显示此图标,线控器 按键被锁定,操作无效。 除霜 多风感,部分机型适用。 童锁, 若设置童锁, 显示此图标, 若无童锁, 无此图标。 智能模式 制冷模式 制热模式 送风模式 除湿模式...
  • Page 44 线控器功能说明 拨码说明 默认设置 变频机型 定频机型 环温显示 环温不显示 采集电脑板环温 采集线控器环温 功能循环简约版 功能循环普通版 固定老协议 新老协议自适应 预留 预留 无摆风 有摆风 电加热手动开启 电加热自动开启 特殊功能的设置 5 秒内连续操作功能键 设置功能 蜂鸣器回响 4 声,设置“掉电记忆” 开机 + 功能键 10 下 蜂鸣器回响 2 声,取消“掉电记忆”...
  • Page 45 5 秒内连续操作功能键 设置功能 1. 回响 7 声设置童锁功能,回响 2 声解除童锁功能; 2. 与长按风速键 + 功能键持续 5 秒 设定的童锁为“或”关系;同时 功能键 12 下设置童锁 生效,相互作用(两者可以相互 功能键 4 下解除童锁 设置相互取消)。 3. 童锁下,功能键只是用来解除童 锁,按功能键有按键响应,但不 响应功能对应图标。 蜂鸣器回响 3 声,温度区显环温持 关机 + 功能键 10 下 续 5 秒(拨码选择不显示环温时, 即拨码 SW2 为 OFF 时) 开机...
  • Page 46 初始化 1. 上电后,线控器全显 5 秒之后,初始化结束。 2. 声音提示:按下开关机键开机时,蜂鸣器短响两声。按下开 关机键关机时,蜂鸣器长响一声。接收其它指令时,蜂鸣器 响一声。 屏幕保护 1. 关机非屏保状态下,长按 键和 键 5s,可对屏保时间进 行设置,屏保时间在左上角冒号后的两位 88 处静止显示, 通过上下键对屏保时间进行调节,按功能键确定。 2. 屏保时间为 0s( 开机背光一直点亮 )、15s、30s、60s。默 认值为 15s。非首次进入,若上次更改,则显示上次更改后 的屏保时间。 3. 屏保时间更改过程中,按开关机键,退出屏保时间设置功能, 屏保时间恢复调整前状态,同时执行开机动作。 4. 开机,背光点亮,关机,背光关掉;开机时,树叶图标亮(无 论背光是否点亮),关机后,树叶图标熄灭。 5. 为了便于用户调整时钟,当线控器上电后为关机状态时,背 光灯亮,当开机再关机时,背光正常关闭。 6. 当线控器处于关机状态时,按除开关键的任意键仅是触发点 亮背光,不执行按键响应操作,当按开关键时,背光点亮并 同时执行开机动作,当线控器处于开机状态并已处于屏幕保 护时,按所有按键均为解除屏幕保护,不下发按键指令。...
  • Page 47 7. 关机状态下, 显示时钟、 环温 (当 SW2 为 ON, 即显示环温时) 、 定时时间(若设置了定时)以及新风图标(仅在关机情况下 设定新风功能时显示) ; 关机状态下, 可进行时钟、 定时、 新风、 童锁、温度补偿参数调整、环温显示的设定。 时钟功能 1. 按功能键,当 闪烁时,再次按功能键,则 与当前的 AM 或 PM 进行闪烁,表示时间可调,通过上下键对当前的 时钟进行调整,调整完成后,再次按功能键确定,时钟图标 与时间固定显示,时钟按新调整时间开始走;若设定过程中 未按确定键或 10 秒内未调整时间,则时钟退出可调状态, 恢复调整前时间。 2. 时钟调整状态:按上下键,时钟以 1 分钟为单位变化,上下 键按住不放时,1 秒钟后变化 2 次 / 秒;5 秒钟后变化 10 次 / 秒;10 秒后以...
  • Page 48 定时功能 1. 设置组合方式:定时可以实现定时开、定时关、定时开关。 2. 设置精度:定时精度为 1 分钟;定时设定时间与时钟同步, 当达到定时时间时,定时标志取消,执行定时动作。 3. 定时功能与开关机关系:开关机状态下,都可以设置定时功 能,若设定了定时功能,无论开机或关机,界面都显示定时 时间和定时图标。 4. 定时设定方式:按功能键,通过上下调整键调整到定时功能, 闪烁,再按功能键进入定时时间调整状态,定时图标固定 显示。 ① 设置定时开,显示默认 12:00PM(若设置过定时开,则 显示上次定时开设定时间),ON 和时间的小时位闪烁, 通过上下键调整时间,长按可加速,加速方法同时钟;通 过风速键,切换到 ON 和时间的分钟位 , 调整完成后,按 功能键确定,定时开时间及图标固定显示在界面上。 ② 设置定时关,显示默认 12:00PM(若设置过定时开,则 显示上次定时开设定时间)ON 和时间的小时位闪烁,通 过风速键,切换到 ON 和时间的分钟位;再次按风速键切 换到 OFF 和时间的小时位闪烁,时间显示默认的定时关 时间为 12:00PM(若设置过定时关,则显示上次定时关 设定时间),通过上下键调整时间,通过风速键,切换到...
  • Page 49 ③ 设置定时开关,显示默认 12:00PM(若设置过定时开, 则显示上次定时开设定时间)ON 和时间的小时位闪烁, 通过风速键,切换到 ON 和时间的分钟位;再次按风速键 切换到 OFF 和时间的小时位闪烁,时间显示默认的定时 关时间为 12:00PM(若设置过定时关,则显示上次定时 关设定时间),通过风速键,切换到 OFF 和时间的分钟 位闪烁,再次按风速键,切换到 ON 和 OFF 同时显示, 但 ON 和时间的小时位闪烁,设置定时开 / 关的开的小时 位,再次按风速键, ON 和时间的分钟位闪烁,设置定 时开 / 关的开的分钟位,再次按风速键, OFF 和时间的 小时位闪烁,设置定时开 / 关的关的小时位,再次按风速 键,OFF 和时间的分钟位闪烁,设置定时开 / 关的关的 分钟位,调整完成后按功能键,定时开关时间及图标固定...
  • Page 50 ⑤ 定时与时钟显示方式:定时优先于时钟显示,当未设定定 时时,时间区显示时钟,当已设定定时后,时间区显示定 时时间,此时按功能键可查看时钟,若 10 秒内未按上下 调整键、风速键、模式或功能键,则退出时钟查看,显示 之前设置的定时状态,若按开关键,退出时钟查看状态并 直接执行开关机动作。 ⑥ 定时时间设定要求:所设定时时间与当前的时钟相同以及 定时开与定时关时间相同时,按功能键不能完成确定,保 持当前状态,但蜂鸣器正常发声,若不更改时间,10 秒 内无按键操作后自动退出,此次设置无效。 ⑦ 定时与睡眠关系:定时开关与睡眠相独立,互不干扰,时 间到即执行相应动作,但关机后睡眠设定也同时取消;定 时开时间和睡眠执行的时间相同时,无论定时开和睡眠设 置的先后,后设置的不能设置成功,一直为闪烁待确认状 态,10 秒内无操作,则退出当前设置。 风速 线控器可执行三档风速和七档风速,该功能主要决定于内机。 部分机型适用。 1. 3 档风速: 按 键, 风速按照 [ 自动 ] → [ 低速 ] → [ 中速 ] → [ 高速 ] → [ 自 动...
  • Page 51 2. 7 档风速: 按 键,风速按照 7 档→ 6 档→ 5 档→ 4 档→ 3 档→ 2 档→ 1 档→自动→ 7 档。 其中,1 档风为最高风速。 风速图标显示: : 7 档 : 6 档 : 5 档 : 4 档 : 3 档 : 2 档 : 1 档...
  • Page 52 3. 针对部分机型,若上下摆风角度可调节: 按功能键进入功能循环,上下摆风图标闪烁显示,再次按功 能键,此时上下摆风当前摆风角度闪烁显示 ( 首次上电根据 模式不同,默认角度也不同。非首次上电为上次设置的摆风 角度 )。此时通过上下键可对上下摆风角度进行循环调节。 按上下键调节摆风角度时,按键即发码。连续 10s 无按键操 作,则退出摆风角度调节功能的同时退出功能循环。此时摆 风按最后一次调节的摆风角度显示。若要设置其他功能,如 睡眠等功能,则需再次按功能键进行功能循环。 左右摆风角度可调节: 按功能键进入功能循环,上下摆风图标闪烁显示,此时按上 下键切换至左右摆风图标闪烁显示。再次按功能键,此时左 右摆风的当前摆风角度闪烁显示 ( 首次上电 摆风角度 1,非 首次上电为上次调节的摆风角度 )。此时通过上下键对摆风 角度进行循环调节。按上下键调节摆风角度,按键即发码。 连续 10s 无按键操作,则退出摆风功能的同时退出功能循环。 此时摆风按最后一次调节的摆风角度显示。若要设置其他功 能,如上下摆风等功能,需再次按功能键进入功能循环。 摆风功能的退出: 按风速键、模式键均可退出摆风角度调节功能。调节摆风角 度后,按功能键立即退出摆风功能。调节过程中,连续 10s 无按键操作退出摆风功能,摆风角度按最后调节的摆风角度 执行。摆风角度调节过程中,按开关机键直接执行关机动作, 摆风角度按最后调节的摆风角度执行。...
  • Page 53 滤网 当界面显示“滤网清洗”标志后,功能循环时, 参与循环, 在滤网图标闪烁状态下,按功能键进行滤网标志的清除。 新风 1. 按下功能键,上下键切换到 闪烁时,再次按功能键,设 定新风功能,图标固定显示;若已经设置了新风功能,进行 上述操作,为新风功能的取消。 2. 新风功能设定后,线控器关机时同时下发新风关指令,线控 器开机后,新风功能保持;线控器在关机状态下,按功能键 设定功能时可以设置新风功能,设置完成后,图标显示,线 控器开机,新风功能保持;设置新风功能后,切换模式时, 新风功能保持。 3. 新风功能仅在 SW4 为 OFF 时,参与功能循环,当 SW4 为 ON 时不参与。 电加热 1. 按下功能键,上下键循环到 时,再次按功能键,可以对 电加热功能进行设定和取消;电加热仅在制热模式或智能模 式制热运行时参与功能循环。 2. 当 SW8 为 OFF 时,制热模式下自动开启电加热,显示电 加热图标,自动开启后,可以通过手动取消,取消后,如果 重新开机为制热,或者切换到其他模式再次循环到制热模式 时,电加热自动开启;当...
  • Page 54 3. 在智能模式制热状态下,线控器收到主板发送的制热状态判 断当前为制热运行,电加热参与功能循环,如果是智能模式 非制热状态,电加热不参与循环。 4. 关机状态下,不进行电加热的循环。 健康 1. 按下功能键,通过上下键切换到 闪烁时,再次按功能键, 健康功能设定成功;若已经设置了健康,进行上述操作,则 为健康功能的取消。 2. 健康功能开关机记忆,模式切换记忆;健康功能仅在 SW4 为 OFF 时参与功能循环,当 SW4 为 ON 时不参与。 睡眠 1. 按下功能键,通过上下键切换到 闪烁时,再次按功能键, 此时温度显示区显示 8h(默认为 8h, 非首次设定显示上次 设定的睡眠时间),通过上下键可调整睡眠时间,调整范围 为 1h-8h,调整后,再次按功能键确认,睡眠时间显示 3 秒 后消失,温度区正常显示设定温度 / 环境温度,设定后若想 查看已设定的睡眠时间,需按功能键调整到睡眠功能时,温 度区自动显示已设定时间。若已经设置了睡眠功能,进行上 述操作,则为睡眠功能的取消。...
  • Page 55 强力 / 安静 1. 按下功能键,通过上下键切换到 闪烁时,再次按功能键, 设定安静功能,若已经设置了安静功能,进行上述操作,则 为安静功能的取消;强力功能的设置 / 取消方法同安静。 2. 设置强力 / 安静后,风速显示自动风,此时按风速键,退出 强力 / 安静, 风速回到进入前状态, 再按一次风速键调整风速; 和 不能同时设置,若设置强力即取消之前设置的安静, 若设置安静即取消之前设置的强力,后入为主;设定睡眠时, 不能设定强力,功能循环时,强力图标不参与循环;设定强 力后,再设定睡眠,确定后,强力功能取消。 3. 仅在制冷 / 制热模式下参与功能循环,模式切换时不记忆, 开关机不记忆,无论线控器是否有掉电记忆,掉电后强力安 静均不记忆;强力 / 安静功能仅在 SW4 为 OFF 时参与功能 循环,当 SW4 为 ON 时不参与。 节能...
  • Page 56 华氏 / 摄氏切换 1. 当 前 设 定 温 度 显 示 为 摄 氏, 各 个 模 式 下 的 设 定 温 度 调 至 30 ℃ ( 若 当 前 设 置 节 能 功 能, 则 制 热 模 式 为 节 能 功 能 的 上限值...
  • Page 57 特殊功能 针对部分机型,若内机回复为四面嵌入机型,功能设定需长按 功能键 5 秒进入,按上下键切换至人感 A,人感 B 和人感功能。 1. 人感: 长按 5 秒功能键进入功能循环后,按上下键切换到人感 A(中 间温度显示区 88.8 的第二个 8 字段显示 A,此时不显示温 度和睡眠时间)→人感 B(中间温度显示区第二个 8 字段显 示 b,此时不显示温度和睡眠时间)→人感。 (1) 人感 A 表示跟随人,人感 A 设置完成后,字符 A 取消, 正常显示环温 / 设定温度,人感图标静止显示。 (2) 人感 B 表示避开人,人感 B 设置完成后,字符 b 取消, 正常显示环温...
  • Page 58 2. 四面嵌: 开机状态下, 点按功能键, 显示四面嵌入图标和上下摆风图标。 (1) 首次开机,各模式的初始位置 智能 制热 制冷 除湿 送风 四面摆风 全显 全显 全显 全显 全显 摆风角度 位置 (3) 位置 (5) 位置 (3) 位置 (3) 位置 (3) (2) 开机后, 通过点按功能键进行切换导风板, 按照如下循环。 四面嵌四面同控→四面嵌 1 →四面嵌 2 →四面嵌 3 →四 面嵌...
  • Page 59 3. 摆风角度 (1) 1:位置一; 2:位置二; 3:位置三; 4:位置四; 5: 位置五; 6:位置六(预留) (2) 摆风角度循环方式为:位置一→位置二→位置三→位置 四→位置五→自动→位置一 (3) 自动风:1 → 2 → 3 → 4 → 5 → 4 → 3 → 2 → 1 循环显 示 (4) 开机后首次进入摆风默认角度如 (1) 表中所述,摆风角度 从默认位置通过上下键进行循环,比如当前在角度 3,按上 键到角度 2,按下键到角度 4;若非首次进入,摆风角度从 上次调整后的角度开始循环。...
  • Page 60 节能参数设定 1. 开机 + 制冷模式 +30℃条件下,长按风速键 + 上键持续 5 秒, 则在左上角前两个 88 处,显示制冷节能参数,并显示设置 图标 ,默认值为 23℃,即设置节能后制冷和除湿模式的 温度调整范围为 23-30℃;制冷节能参数可以通过上下键进 行调整,通过功能键确定;仅在制冷和除湿模式下有效。 2. 开机 + 制热模式 +16℃条件下,长按风速键 + 下键持续 5 秒, 则在左上角前两个 88 处显示制热节能参数,并显示设置图 标 ,默认值为 26℃,即设置节能后制热模式的温度调整 范围为 16-26℃;制热节能参数可以通过上下键进行调整, 通过功能键进行确定;仅在制热模式下有效; 3. 如果设定节能功能后,设置进入强制制冷,强制过程中发码 为 16℃,退出强制制冷后,回到节能的限制温度。 故障查询...
  • Page 61 4. 线控器 4 分钟与内机不能正常通讯,则线控器显示 E8 和故 障小图标,但线控器仍可以正常按键操作,调整温度时, 显示设定的温度,3 秒内无按键操作后温度显示区再次显示 E8,若通讯恢复,故障自动解除。 童锁 1. 为防止误操作,可以使用键盘锁定功能,同时按风速键和功 能键持续 5 秒,界面显示童锁小图标 ,设置后除功能键 外其它按键不可用(功能键可用于解除童锁),童锁状态下, 进行上述动作为取消童锁。 2. 同时按风速键和功能键持续 5 秒与 5 秒内连续按功能键 12 下和 4 下设置和取消童锁功能为或的关系,可相互作用。 配套集中控制器 /130 当收到内机远程锁定(状态,非指令)为 1,则显示 ,所有 按键不可用,也不接受遥控器信号。...
  • Page 62 掉电记忆 1. 开机非屏保状态下,在 5 秒内连续按动功能键 10 次,蜂鸣 器连响 4 声,设定掉电记忆功能。设定后,系统的开关机状 态、 运行模式、 设定风速、 设定温度、 摆风状态、 电加热状态、 健康及新风状态在每次设定后进行记忆,掉电后再上电,系 统按照掉电前所记忆的状态继续运行。掉电记忆功能已经设 定,在开机非屏保状态下,在 5 秒内连续按动功能键 10 次, 蜂鸣器连响 2 声,取消掉电记忆功能。系统所有运行状态不 再记忆,掉电后再上电,线控器处于关机状态,开机后为智 能模式、自动风、24℃。在设定掉电记忆后,如果掉电前设 定定时或者睡眠,那么上电后线控器先进入关机状态,按开 关机键进入关机前的状态。 2. 掉电记忆功能设定后,若线控器 EEPROM 损坏,线控器自 动按无掉电记忆状态运行。 3. 故障、节能参数和节能使能位、温度补偿为底层参数,无论 有无掉电记忆,均记忆。 温度补偿的设定 1. 关机非屏保状态下,长按风速键持续 10 秒,温度区显示温度 补偿值,...
  • Page 63 强制制冷 在关机状态下按开关机键,按键在 5 秒内抬起,执行开机功能, 蜂鸣器短叫两声,若连续按住开关机键 5 秒以上后再抬起,蜂 鸣器短响两声,进入强制制冷,此时线控器状态为开机、制冷 模式、16℃、风速为高速,温度显示区显示 LL,且以固定频率 闪烁,通讯里发强制制冷标志。按任意键或接收遥控器信号, 退出强制制冷并发码。 额定制冷运转 开机状态,制冷,高速,16℃(如果有节能设置,则按照节能 限制最低温度),5 秒内连续按功能键 8 次,蜂鸣器回响 5 声 进入额定制冷运转模式,风速为高速,摆叶为制冷标准模式。 空调器处于额定制冷运转状态中,遥控或按任意键改变当前状 态,主机按照重新设定状态运行。 额定制热运转 开机状态,制热,高速,30℃(如果有节能设置,则按照节能 限制最高温度),5 秒内连续按功能键 8 次,蜂鸣器回响 5 声 进入额定制热运转模式,风速为高速,摆叶为制热标准模式。 空调器处于额定制热运转状态中,遥控或按任意键改变当前状 态,主机按照重新设定状态运行。...
  • Page 64 室温显示 1. 线控器出厂默认显示设定温度,不显示环境温度,但是可以 通过快捷键设定显示环温,实现过程如下:关机非屏保状态 下,5 秒内按功能键 10 次,蜂鸣器响 3 声,温度区显示环 境温度 5 秒,5 秒后自动退出。 2. 显示环温也可以通过拨码 SW2 设定,当 SW2 为 ON 时, 线控器温度区显示环温。 强制除霜 在制热、高速、30℃(若有节能限制,调整到节能上限温度) 的条件下,5 秒内连续按功能键 6 次,蜂鸣器连响 3 声,线控 器向主板发送强制除霜信号, 闪烁 3 下后取消。 红外接收 1. 当线控器接收到遥控器发来的信号时,线控器数据更新并显 示设定功能图标,对于线控器不具备的功能,界面不显示, 线控器接收成功后,蜂鸣器发声,蜂鸣器响应的方式同线控 器自行设定的时候响声一致;当线控器接收失败时,蜂鸣器...
  • Page 65 空气质量参数显示 ( 部分机型适用 ) 1. 内机支持空气质量参数,左上角 8 字段显示空气质量参数。 2. 显示对应关系如下: 参数 界面显示 PM2.5 P+ 数值 甲醛 F+ 数值 TVOC V+ 数值 C+ 数值 湿度 S+ 数值 PM2.5、CO 及湿度数值信息均为整数,直接读取即可。 而甲醛及 TVOC 数值为小数,冒号代替小数点。 3. 若当前设置定时功能,优先显示定时功能。 多风感(部分机型适用) 1. 设置方式: 按 键,通过 键切换到多风感图标 闪烁时,按 键确定,退回主界面,并开启多风感功能,多风感图标...
  • Page 66 线控器接线说明 1. 首先将通讯线穿过后盖上的孔位。 按此卡扣,开启线控器后盖。 暗盒...
  • Page 67 2. 再将后盖固定到暗盒上,然后将通讯线插到线控器的接口, 最后将线控器前盖扣到后盖上,安装完成。 电脑板端子 (红色) 此端有屏蔽保护线需 接内机地线 线控器端子 (白色)...