Download Print this page
Frigidaire GLGT1142CS1 Wiring Diagram
Frigidaire GLGT1142CS1 Wiring Diagram

Frigidaire GLGT1142CS1 Wiring Diagram

Frigidaire glgt1142cs1 gas laundry center: release note
Hide thumbs Also See for GLGT1142CS1:

Advertisement

Quick Links

CAUTION: DISCONNECT ELECTRIC CURRENT BEFORE SERVICING. LABEL
WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
C
TERM
O
A
F
N
C
I
C
T
T
CIRCUIT
WASH
X
I
A
A
E
(15 MIN)
C
V
M
E
D
T
P
1
T
FILL CONTROL
0
2
3
B
NOT USED
4
T
WASH FILL
2
5
6
B
RINSE FILL
7
T
WATER TEMP
4
8
9
B
10
T
SPIN DIR
6
11
12
B
AGITATE DIR
13
T
AGITATE DIR
8
14
15
B
SPIN DIR
16
T
AGIT CONTROL
10
17
18
B
PUMP
19
T
SPIN CONTROL
12
20
21
B
HIGH SPEED MOTOR
22
T
SPIN CONTROL
14
23
24
B
LOW SPEED MOTOR
TAN/
BLK
T16
10
T18
T22
T1
0
T7
4
T8
T4
T5
2
T9
T6
TIMER
MOTOR
T15
6
T11
T14
8
T10
T13
12
T21
14
T24
CIRCLED NUMBERS
INDICATE CAM
WASHER TIMER
120 VAC
L1
RED/BLK
TO L1
CONNECTOR
BLK
BLK
BUZZER
B
H
DRYER TIMER
NOTE:
DASHED LINES INDICATE
CIRCUITS THAT ARE NOT
IN ALL MODELS.
REGULAR
EX. RINSE
OFF
PUMP
PUMP
PUMP
(6 MIN)
(15 MIN)
(9 MIN)
(3)
(3)
P
P
P
A
A
A
PRESSURE
SWITCH
LID SWITCH
FULL
3
TAN/
BLK
2
1
EMPTY
1
RED/WHT
2
BLK/
RED
PUMP
MOTOR
WHT/RED
RED
LID LOCK
YELLOW
YELLOW
F
H
PINK
BLK/
H
WHT/PURP
RED
FF
C
C
TEMP SWITCH
BLUE
WATER
VALVE
BLUE
BLK/RED
PURP
CAPACITOR
ORG
ORG
RED
MOTOR
M5
START
BRN
HIGH
M6
GRAY
LOW
M2
N
TO NEUTRAL
WHT
CONNECTOR
WHT
WHT
C
DRUM
LIGHT
NO
NC
GRAY
WHT
DOOR
SWITCH
BRN
C
M4
OPTION
TIMER
SWITCH
MOTOR
S
TM
X
TEST
BRN
LEADS
TAN
WHT
CONTROL
THERMOSTAT
ORG
1
A
TAN
4
1.5 K
THERMOSTAT
HEATER
1.5 K
2 K
5
BLUE
FABRIC SELECTOR
SWITCH
ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
VERIFY PROPER OPERATION AFTER SERVICING.
PERM. PRESS
OFF
WASH
PUMP
PUMP
(12 MIN)
(6 MIN)
(6 MIN)
(3)
P
A
P
P
A
TO DRYER
NEUTRAL
SPRAY=A
CONNECTION
WHT
WHT
MOTOR/PUMP PAUSE = P
DETAIL FOR FILL CONTROL SPRAY SUBINTERVAL
AND PAUSE FOR MOTOR/PUMP CONTROL CIRCUITS.
BLK
TO DRYER L1
CONNECTOR
24
21
23
20
22
19
TIMER PLUG-MALE
FABRIC SELECTOR SWITCH
POSITION
FUNCTION
1
HIGH
2
MEDIUM
3
MEDIUM/LOW
M1
4
LOW
M3
M7
O
F
F
CAM
CIRCUIT
1
B-A HEATER
1B
B-S MOTOR
2
B-C MOTOR
3
X-TM TIMER MOTOR
4B
X-H BUZZER
START
SWITCH
GRAY
M1
M6
START
GRN
RUN
CABINET
M5
M2
MOTOR
BASE
TAN
TAN
P8
P1
RED
P5
ELECTRONIC
CONTACT
MOISTURE
SENSOR
SENSOR
P4
RED
CONTROL
GAS CONTROL VALVE
2
P2
HOLDING COIL
ORG
SECONDARY
3
BLK
ORG
COIL
4
HIGH LIMIT
THERMOSTAT
5
ORG
WHT
PURP
THIS HARNESS WIRE
SENSOR
NOT FUNCTIONAL
ON THIS MODEL
KNITS & DELICATE
OFF
OFF
WASH
PUMP
PUMP
(6 MIN)
(6 MIN)
(6 MIN)
(3)
P
A
P
P
A
10 SEC (REF)
20±6 SEC
180 SEC
12 SEC (REF)
50 SEC MAX
WASH/RINSE
HOT/COLD
WARM/WARM (OPT)
COLD/COLD
18
15
12
9
6
3
WARM/COLD
17
14
11
8
5
2
16
13
10
7
4
1
(END VIEW)
RESISTANCE
OPEN CIRCUIT
3K±5%
1.5K ±5%
10 MAX
CYCLES
EX
O
O
AUTO DRY
TIMED DRY
F
CARE
F
58.75 MIN
90 MIN
F
F
15 MIN
A
B
YEL
BOOSTER
1
COIL
WHT
3
WHT
WHT
IGNITER
SOAK
PREWASH
OFF
SOAK
PUMP
(12 MIN)
(6 MIN)
(3)
(3)
WIRING CODES
PLUG-IN TIMER TERMINAL
QUICK DISCONNECT TERMINAL
CONNECTION
NO CONNECTION
MOTOR SWITCH
SPLICE
MOTOR PROTECTOR
CHASSIS (CABINET) GROUND
SCREW TERMINAL
HARNESS CONNECTOR TERMINAL
INSULATED TERMINAL
TEMPERATURE SWITCH CIRCUIT
F-H
FF-H
FF-C
X
O
O
O
X
X
O
O
X
X
O
X
X=CLOSED
O=OPEN
NOTES;
1. ALL WIRING MUST CONFORM TO LOCAL
ELECTRICAL CODES.
2. CONNECT DRYER TO 15 AMP INDIVIDUAL
BRANCH CIRCUIT.
3. DRYER TIMER3. SHOWN IN OFF POSITION
DOOR SWITCH CLOSED, MOTOR AT REST,
THERMOSTAT CLOSED. AND FABRIC
SELECTOR SWITCH AT HIGH HEAT.
WASHER TIMER SHOWN IN ON POSITION
TEMPERATURE SELECTOR SWITCH AT
HOT WASH/COLD RINSE, AND
PRESSURE SWITCH FULL.
AIR FLUFF
22.5 MIN
A
A
THE BAR CHART ABOVE REPRESENTS ONE
COMPLETE REVOLUTION OF TIMER SHAFT.
SHADED PORTION OF BAR CHART INDICATES
THE PROPORTIONAL TIMES THAT INTERNAL
TIMER CONTACTS ARE CLOSED.
BUZZER
A
CIRCUIT "X-H" WILL CLOSE FOR 5 SEC ±3 SEC 1 TO
2 TIMES IN THIS AREA. WHEN 2 CLOSURES OCCUR
THEY WILL BE 5 MIN. APART.
B
CIRCUIT "X-H" WILL CLOSE FOR 5 SEC ±3 SEC 5 TO
7 TIMES IN THIS AREA. THE CLOSURES WILL BE
5 MINUTES APART.
WIRING DIAGRAM
134217800 A

Advertisement

loading