2. Position the control panel cover/manual tube as-
sembly onto the control panel (Fig. 1573).
Fig 1573
3. Install 4 screws (2 on the left, 2 on the right) secur-
ing the control panel cover to the control panel (Fig.
1574).
Fig 1574
4. Connect the negative battery cable to the battery.
Floating Deck Mid-Size Service Manual
Kill Relay Replacement (T-2)
Note: The Manual Tube assembly and Control Panel
Cover Bracket have been removed for photo
purposes.
Kill Relay Removal (T-2)
1. Turn the engine off and remove the key from the
ignition.
2. Disconnect the negative battery cable from the
battery.
3. Unplug the kill relay from the wire harness (Fig.
1575).
PICT-1923
PICT-1921
ELECTRICAL
Fig 1575
PICT-1937
9
9-55