2288H V5 Server V100R005 User Guide Issue Date 2018-09-04 HUAWEI TECHNOLOGIES CO., LTD.
Page 2
Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS"...
V5, and how to install an OS, replace parts, and install, remove, configure, and troubleshoot the server. You can perform installation, removal, power-on, power-off, basic configuration, OS installation, parts replacement, and troubleshooting of the 2288H V5 by referring to this document. Intended Audience...
User Guide 1 Overview Overview The Huawei FusionServer 2288H V5 (marked H22H-05 on the nameplate) is a 2U 2-socket rack server developed for Internet, Internet data center (IDC), cloud computing, enterprise, and telecom service applications. The 2288H V5 is ideal for IT core services, cloud computing virtualization, high-performance computing, distributed storage, big data processing, enterprise or telecom service applications, and other complex workloads.
Description SN ID (two characters), which is 21. Material identification code (eight characters), that is, processing code. Vendor code (two characters). The value 10 indicates Huawei and other values indicate outsourcing vendors. Year and month (two characters). l The first character indicates the year. Digits 1 to 9 indicate 2001 to 2009, letters A to H indicate 2010 to 2017, letters J to N indicate 2018 to 2022, and letters P to Y indicate 2023 to 2032.
2.3 Rear Panel Components The 2288H V5 has two types of mainboards. One mainboard provides two 10GE and two GE electrical ports. Figure1 Rear panel components 1 shows its rear panel components.
Page 19
Table 2-4 Ports on the rear panel Port Type Quantit Description 10GE 10GBASE-T The 2288H V5 has two types of electrical port mainboards. One mainboard provides two 10GE and two GE electrical ports. The 10GE optical 10GE SFP+ other motherboard provides two 10GE port optical ports and two GE electrical ports.
RAID status to determine whether the RAID array status is abnormal or whether the drive is faulty. For details about command description, see the Huawei V5 Server RAID Controller Card User Guide. Drive activity indicator l Steady green: The drive is inactive.
2-49, and Figure 2-50 show the riser cards supported by the 2288H V5. Figure 2-45 Riser card 1 (universal) When installed in I/O module 1, this riser card provides slots 1 and 3. When installed in I/O module 2, this riser card provides slots 4 and 6.
4.4 Installing the Server on Guide Rails 4.4.1 Installing with L-Shaped Guide Rails L-shaped guide rails are designed for Huawei cabinets. The 2288H V5 servers are stackable when L-shaped guide rails are used. Step 1 Install the floating nuts. Issue 04 (2018-09-04)
Adjustable guide rails are for a cabinet with a depth of 543.5 mm to 848.5 mm (21.40 in. to 33.41 in.) between the front and rear mounting bars. The 2288H V5 servers are not stackable when adjustable guide rails are used. Step 1 Install the adjustable guide rails.
The holding rails are for a cabinet with a distance of 610 mm to 914 mm (24.02 in. to 35.98 in.) between the front and rear mounting bars. The 2288H V5 servers are stackable onto holding rails. Step 1 Install the holding rails.
Ground cable The 2288H V5 server does not provide a separate ground port. l In an AC or HVDC environment, the power cables of AC PSUs are grounded. Ensure that the power cables are in good contact.
----End 4.6.5 Checking the Server There are two methods available for checking the 2288H V5. Use the iBMC CLI or the iBMC WebUI based on the actual situation. For details about CLI commands, see the Huawei Rack Server iBMC User Guide.
Page 110
The SSH service is enabled by default. If the SSH service is disabled, enable it by choosing Configuration > Services on the iBMC WebUI. View the 2288H V5 version information. Check that the 2288H V5 versions meet site requirements. iBMC:/->ipmcget -d ver ------------------- iBMC INFO ------------------- IPMC CPU: Hi1710 IPMI Version: 2.0...
CPLD Version: complex programmable logical device (CPLD) version of the 2288H V5 BIOS Version: BIOS version of the 2288H V5 Active PME Version: active iBMC version of the 2288H V5 Backup PME Version: backup iBMC version of the 2288H V5 Query the health status of the 2288H V5.
The actual information may differ. Step 4 Configure a RAID array. The RAID configuration method varies according to the RAID controller card model. For details, see the Huawei V5 Server RAID Controller Card User Guide. ----End 4.6.8 Configuring the BIOS Figure 4-37 shows the process for configuring the BIOS.
Page 118
If there are multiple boot devices of the same type, you can configure the boot sequence. The following uses PXE as an example. For details about setting other types of devices as boot options, see the Huawei Server Purley Platform BIOS Parameter Reference. Step 1 Choose Advanced > PXE Configuration, and press Enter.
After parts replacement, upgrade the software, firmware, and CPLDs of the new components to either the version in the customer environment (recommended) or to the latest version. For details, see the Huawei Rack Server Upgrade Guide (iBMC) Huawei Server Firmware Upgrade Guide.
5.3.4 Installing an NVMe SSD Step 1 Install the NVMe SSD driver. When Huawei series NVMe SSDs are used, to ensure the stable running of NVMe SSDs, you are advised to install the Huawei-developed NVMe SSD drive. For details about the...
To install a CPU, perform the following steps: NOTICE l Only personnel authorized by Huawei are allowed to install CPUs. l Do not wear ESD gloves because they may damage the pins on the CPU socket. l CPUs in the same server must be of the same model.
Page 163
If a CPU socket has bent pins or contains foreign matter, or the bonding pad is damaged, stop the installation and contact Huawei technical support. Step 20 Align the two diagonal holes of the heat sink with the positioning pins on the CPU socket and gently position the heat sink in place.
Note: The maximum number of DIMMs is based on 2-CPU configuration. If the server has only one CPU, the maximum number of DIMMs is half the value in this table. 5.13.2 Memory Subsystem Architecture The 2288H V5 provides 24 DDR4 DIMM slots. Each CPU supports six channels. Table 5-5 lists channels for each CPU.
Before removing the TPM/TCM, check whether some TPM/TCM functions have been set on the BIOS. If yes, you need to set these functions again after replacing the TPM/ TCM. For details, see the Huawei Server Purley Platform BIOS Parameter Reference. Issue 04 (2018-09-04)
In this chapter, the screw-in RAID controller card is used to illustrate cable connections, which are the same for connecting a PCIe plug-in RAID controller card. Huawei Part Number A Huawei part number uniquely identifies a server component. You can find the number on a component or component package. Figure 7-1 shows a cable label with the part number 04151201.
OS. The BIOS also provides the advanced configuration and power interface (ACPI) and hot swap. The Huawei Purley-based server is developed based on Insyde code base and uses a proprietary BIOS. It provides a variety of in-band and out-of-band configuration functions as well as high scalability, and supports customization.
Huawei Server Purley Platform BIOS Parameter Reference. 8.2 iBMC The iBMC is a Huawei proprietary intelligent management system that remotely manages servers. The iBMC complies with Intelligent Platform Management Interface (IPMI) standards and Simple Network Management Protocol (SNMP). It provides various functions, including keyboard, video, and mouse (KVM) redirection, text console redirection, remote virtual media, and reliable hardware monitoring and management.
8.3 Upgrading the System NOTE Upgrade server drivers, firmware, and management software as needed. Obtaining Upgrade Packages and Documents Obtain the upgrade package from http://e.huawei.com/us/. The download path is: Support > Software Download > IT > Server > FusionServer > Rack Server.
Checker. 8.4 FusionServer Tools uMate uMate is a tool used in the acceptance, deployment, and maintenance scenarios of Huawei servers. It provides a GUI and CLI. uMate provides the inspection, log collection, firmware upgrade, and BIOS/BMC/RAID configuration functions and all functions support batch operations.
If a fault occurs on a server, collect logs for fault diagnosis. Fault diagnosis Fault diagnosis rules and tools help Huawei technical support engineers and maintenance engineers to analyze and rectify faults according to alarms and hardware fault symptoms. Software and firmware upgrade Software and firmware upgrade packages can be downloaded by server model and installed as needed.
11.2 Safety 11.1 Warranty According to the Huawei Warranty Policy for Servers & Storage Products (Warranty Policy for short), the server has a three-year warranty, the DVD drive and iBBU have a one-year warranty, and the software media have a three-month warranty.
Page 258
13 Product Specifications Item Specifications Network port l The 2288H V5 has two types of mainboards. One mainboard provides two 10GE and two GE electrical ports. The other motherboard provides two 10GE optical ports and two GE electrical ports. NOTE...
Page 259
P4, P100, and M10 GPUs NOTE l Use the Huawei Server Compatibility Checker to check the PCIe cards supported by the 2288H V5. For PCIe cards not listed in the Huawei Server Compatibility Checker, contact your local Huawei sales representative or Huawei technical support.
– Provides the GUI, virtual KVM, virtual media, Serial Over LAN (SOL), intelligent power supply, remote control, and hardware monitoring features. l NC-SI l Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios Security...
Page 261
Cabinet depth: ≥ 1000 mm (39.37 in.) Requirements for guide rail installation: l L-shaped guide rails: apply only to a Huawei cabinet. l Adjustable guide rails: apply to a cabinet with a distance of 543.5 mm to 848.5 mm (21.40 in. to 33.41 in.) between the front and rear mounting bars.
Page 272
You are advised to run the ipmcget -d serialdir command to view the value options. For the 2288H V5 server, the options are as follows: – 0: switch from PANEL COM to SYS – 1: switch from PANEL COM to iBMC COM –...
----End 14.4 Logging In to the Server Using the IRC The independent remote console (IRC) is a tool developed based on the Huawei server management software iBMC. You can use this tool to remotely access and manage the server, without worrying about browser and JRE compatibility.
Base. Huawei Technical Support If a fault persists after taking troubleshooting measures specified in documents, contact technical support at your local Huawei office. If your local Huawei office is not available, contact Huawei technical support as follows: Issue 04 (2018-09-04)
Calculator calculate server power Calculator. consumption with different configurations. 15.3 Maintenance Tools Table 15-2 lists the software tools required for routine maintenance of Huawei servers. Table 15-2 Software tools for routine maintenance Tool Server Model and Description Software Version FusionServer...
2288H V5 Server User Guide A Appendix Appendix A.1 Logical Structure Figure A-1 2288H V5 logical structure ® ® The 2288H V5 supports two Intel Xeon Scalable series CPUs and 24 DDR4 DIMMs. The CPUs interconnect with each other through Ultra Path Interconnect (UPI) links at speeds of up to 10.4 GT/s.
A.2 RAS Features Table A-1 describes the reliability, availability, and serviceability (RAS) features supported by the 2288H V5. You can configure these features for better performance. NOTE For details about how to configure these features, see the Huawei Server Purley Platform BIOS Parameter Reference.
BIOS Abstraction Layer The BIOS processes errors and reports the error for Error Handling information to the OS and 2288H V5 in compliance with specifications to improve system serviceability. BIOS-based Predictive The BIOS provides physical unit information for...