ABB COM600 User Manual
ABB COM600 User Manual

ABB COM600 User Manual

Station automation, 3.4, dnp 3.0 lan/wan slave (opc)
Hide thumbs Also See for COM600:
Table of Contents

Advertisement

Station Automation COM600 3.4
DNP 3.0 LAN/WAN Slave (OPC) User's
Manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB COM600

  • Page 1 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual...
  • Page 3: Table Of Contents

    1MRS755496 Station Automation COM600 3.4 Issued: 10.3.2005 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Version: F/06.11.2009 Contents: About this manual .................. 7 1.1. Copyrights ..................7 1.2. Trademarks ..................7 1.3. General ..................7 1.4. Document conventions ..............8 1.5.
  • Page 4 3.4.5.19. WYE ............35 Operation ....................37 4.1. About this section ................. 37 4.2. Activating COM600 with new configurations ....... 37 4.3. DNP LAN Slave OPC Client diagnostics ........37 4.4. DNP LAN Channel diagnostics ........... 38 4.5. DNP LAN IED diagnostics ............39 4.6.
  • Page 5 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Appendix 1 ....................55 Device profile ..................55 Index ......................81...
  • Page 7: About This Manual

    In no event shall ABB Oy be liable for direct, indirect, special, incidental, or consequential damages of any nature or kind arising from the use of this document, nor shall ABB Oy be liable for incidental or consequential damages arising from use of any software or hardware described in this document.
  • Page 8: Document Conventions

    Operation This section covers the basic operation procedures you can carry out when transferring or activating Station Automation COM600 (later referred to as COM600) with new configurations. You are also given instructions on how to monitor and control the DNP communica- tion.
  • Page 9: Use Of Symbols

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Entered value is not valid. The value must be 0 - 30 • You can be asked to enter the string MIF349 in a field. The string is shown as follows...
  • Page 10: Terminology

    Terminology The following is a list of terms associated with COM600 that you should be familiar with. The list contains terms that are unique to ABB or have a usage or definition that is different from standard industry usage. Term...
  • Page 11: Abbreviations

    XML-based description language for configurations of electrical guage; SCL substation IEDs. Defined in IEC 61850 standard. 1.7. Abbreviations The following is a list of abbreviations associated with COM600 that you should be familiar with. See also 1.6, Terminology. Abbreviation Description Alarms and Events...
  • Page 12: Related Documents

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Abbreviation Description Request To Send Substation Automation SAB600 Station Automation Builder 600 Substation Configuration Language Single Line Diagram SNTP Simple Network Time Protocol SOAP Simple Object Access Protocol...
  • Page 13: Introduction

    The DNP LAN Slave OPC Client is configured using SAB600. SAB600 can also be used for diagnosing and controlling the operation of the DNP LAN Slave OPC Client. COM600 has a web server that can be used for remote diagnostic of the Gateway including the DNP LAN Slave OPC Client.
  • Page 14: Configuration

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Configuration 3.1. About this section This section guides you in the configuration tasks required before you can start using the DNP LAN Slave OPC Client. For information on the IEC 61850 data modeling, refer to COM600 User's Manual.
  • Page 15 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual DNP_Slave_LANWAN_configuration_overview.bmp Figure 3.2-1 Example view of SAB600 The configuration work can basically be divided into two separate tasks: 1. building an object tree, and 2. configuring object properties.
  • Page 16: Building Object Tree

    An object representing the DNP LAN Slave OPC Client. DNP LAN Channel An object representing the channel DNP LAN IED A DNP LAN IED is used for a virtual station in COM600 representing the slave stations visible to the DNP master system. Data Object (DO)
  • Page 17: Adding Dnp Lan Slave Opc Client Object

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 3.3.2. Adding DNP LAN Slave OPC Client object To add the OPC client object: 1. Add the DNP LAN Slave OPC Client object in the Communication structure by selecting the Gateway object.
  • Page 18: Configuring Objects

    5. At this point, click Apply to create the cross-references (to connect the data objects to the DNP LAN IED). DNP_LAN_Slave_Cross_References.bmp Figure 3.3.5-1 The Cross References window For more detailed information about the Cross-References function, see Cross-References function in COM600 User's Manual. 3.4. Configuring objects 3.4.1. General about configuring objects After the objects have been added, configure the object properties.
  • Page 19 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual To configure an object: 1. Select an object in the object tree of the communication structure. The object properties appear now in the Object Properties window. The proper- ties and their values can be viewed as shown in Figure 3.4.1-1.
  • Page 20: Configuring Dnp Lan Slave Opc Client Properties

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 3.4.2. Configuring DNP LAN Slave OPC Client properties Table 3.4.2-1 lists the configurable DNP LAN Slave OPC Client properties and value ranges for them. The actual configuration by using SAB600 is performed as described in 3.2, Overview of configuration.
  • Page 21: Configuring Dnp Lan Ied Properties

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Table 3.4.3-1 DNP LAN Channel properties Property / Para- Value or Value range/ Default Description meter Basic In Use In use Specifies whether the channel is in use or not.
  • Page 22 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Table 3.4.4-1 DNP LAN IED properties Name Value/Value range Description Basic Diagnostics Enabled True Specifies whether diagnostic AE events are sent for the station. False Default: False In Use In use Defines if the IED is in use or not.
  • Page 23: Configuring Data Objects

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Name Value/Value range Description Information Address 1...3 The length of a data object address used Length in the DNP 3.0 messages. Default: 2 Time Handling Time Synchroniza- Handled, time set Positive...
  • Page 24: Directional Protection Activation Information (Acd)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Clicking Apply connects the data objects to the IED. The connected data objects appears as child objects for the IED. The cross reference information can then be also modified by selecting the data object and using the object properties window.
  • Page 25: Protection Activation Information (Act)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Indication Object Binary input (1, 2) Object number for indication. Binary output (10) Default: Binary input (1, 2) 3.4.5.3.
  • Page 26: Analog Set Point (Apc)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 3.4.5.4. Analog set point (APC) Table 3.4.5.4-1 Configurable APC properties Property/ Para- Value or Value range/ Default Description meter Basic Common Data Common data class according to IEC Class 61850.
  • Page 27: Binary Controlled Step Position Information (Bsc)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 3.4.5.6. Binary controlled step position information (BSC) Table 3.4.5.6-1 Configurable BSC properties Property/ Parameter Value or Value range/ Description Default Basic Common Data Class Common data class according to IEC 61850.
  • Page 28: Delta (Del)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Data Class Spe- cific Indication Object Analog input (30, 32) Object number for indication. Analog output (40) Default: Analog input (30, 32)
  • Page 29: Controllable Double Point (Dpc)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Unit Default: Dimensionless SI unit for measurement as described in IEC61850 3.4.5.9. Controllable double point (DPC) Table 3.4.5.9-1 Configurable DPC properties...
  • Page 30: Device Name Plate (Dpl)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Operate True DNP direct operate of SBO (function code configuration). False Default: True 3.4.5.10. Device Name Plate (DPL) Table 3.4.5.10-1 Configurable LPL properties...
  • Page 31: Controllable Integer Status (Inc)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Index BFI -1 to 65535 Index for Breaker Failure Indication. Default: -1 Data Class Spe- cific Indication Object Binaryinput(1,2) Object number for indication.
  • Page 32: Integer Status (Ins)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 3.4.5.13. Integer status (INS) Table 3.4.5.13-1 Configurable INS properties Property/ Para- Value or Value range/ Default Description meter Basic Common Data Common data class according to IEC Class 61850.
  • Page 33: Logical Node Name Plate (Lpl)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Indication Object Analog input (30, 32) Object number for indication. Analog output (40) Default: Analog input (30, 32) 3.4.5.15.
  • Page 34: Controllable Single Point (Spc)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Indication Object Analog input (30, 32) Data object number for indication. Analog output (40) Default: Analog input (30, 32)
  • Page 35: Single Point Status (Sps)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Operate Direct Operate Specifies using two-step, select-before- operate method for issuing control request Select Before Operate or not. Default: Direct Operate 3.4.5.18.
  • Page 36 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property/ Para- Value or Value range/ Default Description meter Phase A Index -1 to 65535 Phase A Index Default: -1 Phase B Index -1 to 65535 Phase B Index...
  • Page 37: Operation

    After this, you can, for example, monitor and control the condition of connections in network. This is done by using the Online diagnostics function in SAB600. 4.2. Activating COM600 with new configurations For information about activating COM600 with new configuration, see COM600 User’s Manual. 4.3. DNP LAN Slave OPC Client diagnostics...
  • Page 38: Dnp Lan Channel Diagnostics

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual A040347.jpg Figure 4.3-2 Event log file 4.4. DNP LAN Channel diagnostics The DNP LANChannel activity can be monitored with the Online diagnostics function. You can also take a channel into use or out of use as described in this section.
  • Page 39: Dnp Lan Ied Diagnostics

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 4.5. DNP LAN IED diagnostics The DNP LAN IED communication can be monitored with the Online diagnostics function. You can also take a device into use or out of use as described in this section.
  • Page 40: Signal Diagnostics

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual A040349.jpg Figure 4.5-1 DNP LAN IED Online diagnostics 4.6. Signal diagnostics The DNP LAN Slave OPC client has a diagnostic function which makes it possible to monitor the flow of process data changes and commands. The diagnostic function is activated by marking the Diagnostic Events Enabled check box, located in the Online diagnostics function of the DNP LAN IED.
  • Page 41 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual A040350.jpg Figure 4.6-1 DNP LAN Slave OPC Client Diagnostic AE client Detailed information about field values (ASDU types, qualifier values and so on) can be found in the DNP standard documentation.
  • Page 42: Technical Reference

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Technical reference 5.1. About this section This section provides reference information about the following issues: • IEC 61850 data modeling • Attributes • Status codes 5.2. IEC 61850 data modeling 5.2.1.
  • Page 43: Double Point Status (Dps)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 5.2.3. Double point status (DPS) Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element stVal ENUMERATED Intermediate-state state (0=OFF, VT_I4 1=ON) off (1)
  • Page 44: Directional Protection Activation Information (Acd)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element TimeStamp <none> | Time of occurence 5.2.6. Directional protection activation information (ACD) The ACT-related directional protection activation information is processed like ACT.
  • Page 45: Measured Value (Mv)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 5.2.8. Measured value (MV) Name Type Value/ Value Mandat- Protection inform- OPC data types range ory/Optional ation element AnalogueValue CurrentValue VT_R4 Quality DNP status VT_I4 TimeStamp <none> | Time of...
  • Page 46: Delta (Del)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element phsC.cVal.mag AnalogueValue Phase C Current VT_R4 Value phsC.q Quality VT_I4 DNP status phsC.t TimeStamp VT_DATE <none>...
  • Page 47: Controllable Single Point (Spc)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element phsCA.cVal.mag q AnalogueValue Phase CA Current VT_R4 Value phsCA.q Quality VT_I4 DNP status phsCA.t...
  • Page 48: Controllable Integer Status (Inc)

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element stSeld BOOLEAN FALSE | TRUE State (0=OFF, VT_BOOL 1=ON) 5.2.14. Controllable integer status (INC)
  • Page 49: Analogue Set Point (Apc)

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Name Type Value/ Value Mandat- Protocol informa- OPC data types range ory/Optional tion element TimeStamp <none> | Time of V_DATE occurrence 5.2.17. Analogue set point (APC) Name Type...
  • Page 50: Attributes

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 13904 No more events can be written to one of the unsolicited message queues since the queue is full. 13905 Internal message buffer full error. 13906 Internal message filling error.
  • Page 51: Dnp Lan Slave Opc Client Attributes

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual 5.4.2. DNP LAN Slave OPC Client attributes Table 5.4.2-1 DNP LAN Slave OPC Client attributes Property / Para- Value or Value range/ Default Description meter Protocol Stack Ver-...
  • Page 52: Dnp Lan Ied Attributes

    Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property / Para- Value or Value range/ Default Description meter Transmitted Com- The number of transmitted commands. mands Transmitted Replies The number of transmitted replies. Received Messages The number of received data messages.
  • Page 53 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property / Para- Value or Value range/ Default Description meter Object Status When written: Data type: Integer 1 = Re-transmit system mes- Access: No limitations sage Indicates the detailed information about When read: the station device status.
  • Page 54 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Property / Para- Value or Value range/ Default Description meter Queue Diagnostics Data type: Integer Access: No limitations Size of APDU in- queue Size of APDU out- queue...
  • Page 55: Appendix 1

    DNP 3.0 LAN/WAN Slave (OPC) User's Manual Appendix 1 Device profile Table A1-1 Device profile describing the implementation of DNP V3.00 slave pro- tocol in COM600 SUBSET 2: the default subset DNP V3.00DEVICE PROFILE DOCUMENT Vendor Name: ABB Oy Substation Automation Products Device Name: COM600...
  • Page 56 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Requires Data Link Layer Confirmation: [x] Configurable Timeouts while waiting for: Data Link Confirm [ ] None [ ] Fixed at _________ [ ] Variable [x] Configurable Complete Appl. Fragment...
  • Page 57 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Sends/Executes Control Operations: Latch Off [ ] Never [x] Always [ ] Sometimes [ ] Configurable Queue [x] Never [ ] Always [ ] Sometimes [ ] Configurable...
  • Page 58 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Table A1-2 Supported function codes CODE FUNCTION DESCRIPTION Supported Transfer Function Codes Confirm Message fragment confirmation No response Read Request objects from outstation Respond with requested objects Write Store the specified objects to out- station.
  • Page 59 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual CODE FUNCTION DESCRIPTION Supported Freeze with time Copy the specified objects to freeze buffer at specified time Respond with status of operation Freeze with time Copy the specified objects to...
  • Page 60 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual CODE FUNCTION DESCRIPTION Supported Delay Measure- Perform propagation delay meas- ment urement Record current Used in a network application to time allow the Master station and the Outstation to record their time at...
  • Page 61 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) Control Block - All Variations Control Relay 3, 4, 5, 6...
  • Page 62 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 32-Bit Frozen Counter with Time of Freeze 16-Bit Frozen...
  • Page 63 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 16-Bit Delta Counter Change Event without Time 32-Bit Counter...
  • Page 64 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 16-Bit Frozen Delta Counter Event with Time Analog Input -...
  • Page 65 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 32-Bit Analog 129,130 17,28 Change Event without Time...
  • Page 66 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) Time and Date - All Variations Time and Date...
  • Page 67 No Object No Object Table A1-4 Device profile describing the implementation of DNP V3 slave protocol in COM600 SUBSET 3: the used subset is selected using the IED's subset property DNP V3.00DEVICE PROFILE DOCUMENT Vendor Name: ABB Oy Substation Automation Products...
  • Page 68 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual DNP V3.00DEVICE PROFILE DOCUMENT Maximum Data Link Re-tries: Maximum Application Layer Re-tries: [ ] None [ ] None [ ] Fixed at _______________________ [x] Configurable, range 0 to 10...
  • Page 69 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Timeouts while waiting for: Sends/Executes Control Operations: WRITE Binary Outputs [x] Never [ ] Always [ ] Configurable [ ] Sometimes SELECT/OPERATE [ ] Never [x] Always [ ] Configurable...
  • Page 70 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Timeouts while waiting for: [x] Never [ ] Always [ ] Configurable [ ] Sometimes FILL OUT THE FOLLOWING ITEMS FOR SLAVE DEVICES ONLY: Reports Binary Input Change Events when no specific...
  • Page 71 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual CODE FUNCTION DESCRIPTION Supported Read Request objects from outstation Respond with requested objects Write Store the specified objects to out- station. Respond with status of operation Control Function Codes...
  • Page 72 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual CODE FUNCTION DESCRIPTION Supported Application Control Function Codes Cold Restart Perform desired reset sequence Respond with a time object Warm Restart Perform desired partial reset oper- ation Respond with a time object...
  • Page 73 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual CODE FUNCTION DESCRIPTION Supported Confirm Message fragment confirmation Response Response to requested message Unsolicited Mes- Spontaneous message without sage request Supported objects Table A1-6 Supported objects OBJECT Description...
  • Page 74 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) Binary Counter - 1, 7, 8, 9, 10, 22...
  • Page 75 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 32-Bit Frozen Delta Counter with Time of Freeze...
  • Page 76 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 16-Bit Counter Change Event with Time 32-Bit Delta...
  • Page 77 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 16-Bit Analog 00,01,06 129, 130 00, 01 Input...
  • Page 78 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) 16-Bit Analog Change Event with Time Frozen Analog...
  • Page 79 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) Unsynchronized 129, 130 quantity=1 Time and Date Time Delay - All...
  • Page 80 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual OBJECT Description REQUEST Qual RESPONSE Qual Codes (slave must Codes(hex) (master must (hex) parse) parse) Func Codes Func Codes (dec) Small Packed Binary-Coded Decimal Medium Packed Binary-Coded Decimal...
  • Page 81: Index

    1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Index activation information properties ....................... 25 adding channel object ....................17 data object ..................... 17 device object ....................17 OPC client ...................... 17 analog set point properties ....................... 26 application layer ....................
  • Page 82 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual IEC 61850 data modeling ................48 properties ....................... 31 Controllable single point (SPC) IEC 61850 data modeling ................47 properties ....................... 34 data object adding ......................17 configuring ..................... 23 Delta (DEL) IEC 61850 data modeling ................
  • Page 83 1MRS755496 Station Automation COM600 3.4 DNP 3.0 LAN/WAN Slave (OPC) User's Manual WYE ......................45 Integer controlled step position (ISC) properties ....................... 32 Integer status (INS) IEC 61850 data modeling ................43 properties ....................... 32 link layer ......................49 logical node name plate properties .......................
  • Page 84 Station Automation COM600 3.4 1MRS755496 DNP 3.0 LAN/WAN Slave (OPC) User's Manual Single point status (SPS) ................35 WYE ......................35 Protection activation information (ACT) IEC 61850 data modeling ................43 signal diagnostics ..................... 40 Single point status (SPS) IEC 61850 data modeling ................42 properties .......................
  • Page 86 Contact us ABB Oy Distribution Automation P.O. Box 699 FI-65101 VAASA, FINLAND Tel. +358 10 22 11 Fax. +358 10 224 1094 ABB Inc. Distribution Automation 655 Century Point Lake Mary, FL 32746, USA Tel: +1 407 732 2000 Fax: +1 407 732 2335...

Table of Contents