Installation Instructions
IMPORTANT:
Read and save these
instructions.
Installer: Leave Installation Instructions with
homeowner.
Homeowner: Keep Installation Instructions for
future reference. For best performance,
install dryer according to Installation
Instructions. Failure to complete
installation as instructed could void
warranty.
Save Installation Instructions for local
inspector's use.
Part No. 8535845
Set to operate on NATURAL GAS
Have questions about your dryer?
Call your dealer or local authorized service company.
When you call, you will need the dryer model number and serial
number. Both numbers are on the model/serial rating plate located in
the door well behind the dryer door and on front of opening.
Record the numbers here for handy reference:
Model No.
Serial No.
Gas Dryer

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool 8535845

  • Page 1 Record the numbers here for handy reference: future reference. For best performance, install dryer according to Installation Instructions. Failure to complete Model No. installation as instructed could void warranty. Serial No. Save Installation Instructions for local inspector’s use. Part No. 8535845...
  • Page 2 For proper drying Before you begin... WARNING: For your safety the performance: information in this manual The location must provide: must be followed to minimize • Protection from weather and water: Your safety and the safety of the risk of fire or explosion or others are very important.
  • Page 3: Tools Needed For Installation

    • knife certified by AGA or CSA. purchased from your dealer or by • 1/4" nut driver or socket wrench calling Whirlpool Parts & Accessories — 3/8" flare x 3/8" NPT 1-800-442-9991, Mon-Fri: 8am to 9pm female. (CST), Sat: 9am to 4:30pm (CST).
  • Page 4 Door clearance Dryer dimensions dimensions Location must be large enough to fully open dryer door. 42-3/8"* Super-large side swing door (reversible) 3-7/8" 14-1/2" 22-3/4" dryer exhaust 6"* vent 9-1/4" *Dimensions shown with feet 2-1/8" extended 1" from bottom of dryer. gas burner inlet 19-1/8"...
  • Page 5: Electrical Requirements

    Recommended ground Electrical Gas supply method requirements The dryer, when installed, must be electrically grounded in accordance WARNING with local codes, or in the absence of WARNING local codes with the National Electrical Code, ANSI/NFPA 70*. GROUNDING INSTRUCTIONS: This appliance must be grounded. In the event of malfunction or breakdown, Explosion Hazard grounding will reduce the risk of...
  • Page 6 Natural Gas: Supply line requirements: Optional gas line connection method. This dryer is equipped for use with Provide a 1/2-inch IPS rigid gas When acceptable to the gas supplier NATURAL GAS. It is design-certified supply line to the dryer location. and local codes, 3/8-inch approved by CSA International for L.P.
  • Page 7: Exhaust Requirements

    Dura Safe™ venting products are Mobile home installation Exhaust requirements recommended and are available requirements from your dealer. If codes permit, this dryer is suitable Four-inch diameter vent must be for mobile home installations. The WARNING used. installation of the dryer must conform to the U.S.
  • Page 8 Plan the exhaust vent The maximum length of the exhaust exhaust air flow system depends upon: installation acceptable • the type of vent (rigid or flexible better metal). Typical installations exhaust from the rear of the dryer. • the number of elbows used. exhaust 1.
  • Page 9: Installation Steps

    Insert screws in bottom Installation steps holes on left side of diamond cabinet. Tighten screws marking halfway. Position door If installing washer and dryer, install so large end of door dryer first. hinge slot is over screws. Slide door up so screws are in Install vent system bottom of slots.
  • Page 10 manual shutoff Level dryer valve “open” position” to dryer Dryer must be level to reduce noise and assure proper performance. Slide dryer onto cardboard or hardboard before moving across rigid gas floor to prevent floor damage. supply line Turn and reattach outer door panel to inner door panel so handle is on the Move dryer close to its permanent Turn the shutoff valve in the gas...
  • Page 11: Check Operation

    Swivel collar same or opposite wall connection Telescoping Swivel collar sections Extra long band-clamp Beveled edges for dryer allow corner connection installations 18"-29" : Part #4396011 29"-50" : Part #4396014 Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.
  • Page 12 Turn leveling legs all the way in. Slide dryer onto cardboard or hardboard before moving it across the floor to prevent damaging floor covering. Part No. 8535845 Printed in U.S.A. © 2002 Whirlpool Corporation Benton Harbor, Michigan 49022, U.S.A.
  • Page 13: Instrucciones De Instalación

    No completar la instalación cuando los necesite: de acuerdo con las instrucciones podría anular la garantía. Conserve las instrucciones de instalación para Modelo No. uso del inspector de instalaciones eléctricas de su localidad. Serie No. Parte No. 8535845...
  • Page 14 Es su responsabilidad: Antes de empezar... • Llame inmediatamente a la • Observar todos los códigos y compañía de gas desde el reglamentos aplicables. teléfono de un vecino. Siga las • Verificar los requisitos del código: Su seguridad y la seguridad de los instrucciones de la compañía de demás son muy importantes.
  • Page 15 - Tubo metálico nuevo y flexible con aire Dura Safe de su distribuidor o • Guantes diseño certificado por la A.G.A. llamando a Whirlpool Parts & (Asociación Americana de Gas) o • Llave ajustable que se abra a 2.5 Accesories al número 1-800-442-9991, CSA.
  • Page 16: Instalación Empotrada

    Dimensiones de los espacios Dimensiones de la secadora para la puerta El lugar debe ser lo suficientemente grande para que la puerta de la secadora se puede abrir completamente. Puerta lateral Puerta lateral grande supergrande (reversible) (reversible) 17.8 cm 9.8 cm 107.6 cm conducto de 57.8 cm...
  • Page 17: Requisitos Eléctricos

    El cordón de suministro eléctrico debe Requisitos eléctricos Suministro de gas conectarse en un tomacorriente adecuado que haya sido debidamente instalado y puesto a tierra de acuerdo ADVERTENCIA con todos los códigos y reglamentos ADVERTENCIA locales. tomacorriente de puesta a tierra con 3 terminales Peligro de explosión enchufe tripolar...
  • Page 18 Se debe utilizar una combinación de Gas natural: Requisitos de la línea de accesorios para tubos para conectar suministro: Esta secadora está equipada para ser la secadora a la línea de gas. utilizada con GAS NATURAL. Su Proporcione una línea rígida de Se deben utilizar compuestos para diseño está...
  • Page 19 Se recomiendan productos de Requisitos de instalación en Requisitos del salida de aire Dura Safe™ los una casa móvil o rodante cuales puede adquirir de su sistema de salida Si los códigos lo permiten, esta distribuidor. secadora puede instalarse en una de aire Se debe utilizar un conducto de casa móvil o rodante.
  • Page 20 Planifique la instalación La longitud máxima del sistema de flujo de aire de salida salida de aire depende de: del conducto de salida aceptable • el tipo de conducto utilizado (metal mejor rígido o flexible). de aire • el número de codos utilizados. En las instalaciones típicas la salida de aire se 1.
  • Page 21 Saque la rejilla de secado si está tornillos superiores de las bisagras que Etapas de la incluida. Gire el tambor de la secadora están del lado del gabinete. en sentido contrario a las manecillas Levante la puerta hasta que los instalación del reloj para asegurarse de que quitó...
  • Page 22 Cierre la puerta y verifique que la Nivelación de la presa quede alineada con el pestillo secadora (F) de la puerta. Si la puerta no se cierra completamente, deslice el pestillo de la puerta hacia la izquierda La secadora debe estar nivelada o la derecha dentro de la ranura, hasta para reducir el ruido y asegurar su que el pestillo coincida con la presa.
  • Page 23: Conexión Del Gas

    Conexión del gas Salida de aire de la Verifique el secadora funcionamiento Abrazadera Asegúrese si: de 10.2 cm (4 pulg.) no omitió algún paso de la instalación. instaló todas las piezas. Abrazadera instaló debidamente las patas de la de 10.2 cm (4 pulg.) secadora.
  • Page 24 45.7-73.7 cm (18-29 pulg.) Parte No. 4396011 en la pared. 73.7-127 cm (29-50 pulg.) Parte No. 4396014 Dura Safe y Sure Connect son marcas de fábrica de Whirlpool, USA ¿Va a trasladar de lugar Desconecte el soporte de la pared y...