Jet heat mode operation
• While in cooling mode or Fuzzy operation, the Jet Heat key cannot be input. When it is input while in the
Heating mode operation (dehumidification), the Jet Heat mode is operated.
• In the Jet Heat mode, the indoor fan is operated super-high speed for 60 min. at Heating mode operation.
• In the Jet Heat mode, the room temperature is controlled to the setting temperature, 30°C.
• When the sleep timer mode input while the Jet Heat mode operation, the Jet Heat mode has the priority.
• When the Jet Heat key is input, the upper/lower vane is reset to those of the initial Jet heating mode and
then operated in order that the air outflow could reach under flow.
New Chaos swing mode
• Toggle operation is carried out if pressing the Chaos key of the remote control during operation of product.
• Move the vane up or down in interval of 16˚C from the initial vane position.
• Vane speed is different every sector but speed and movement of the vane depends on following graph.
Cooling Operation
Up/Down vane degree
Basic pattern(1)
Basic pattern(2)
Heating Operation
Up/Down Vane degree
Basic pattern(1) Basic pattern(2) Basic pattern(3) Basic pattern(4) Basic pattern(5) Basic pattern(6) Basic pattern(7) Basic pattern(8) Basic pattern(9) Basic pattern(10) Basic pattern(11) Basic pattern(12)
+16 deg.
+8 deg.
Initial position
-16 deg.
-32 deg.
Basic pattern(3)
Basic pattern(4)
Basic pattern(5)
+16 deg.
+8 deg.
Initial position
-16 deg.
-32 deg.
Basic Patten(1)
Vane operation on short change of flow
6ms
12ms
1 cycle
Basic pattern(6)
Basic pattern(7)
Basic pattern(8)
Basic pattern(9) Basic pattern(10) Basic pattern(11) Basic pattern(12)
Basic Patten(1)
Vane operation on short change of flow
6ms
12 ms
1 cycle
Vane operation on middle change of flow
6ms
12ms 6ms
Vane operation on middle change of flow
6ms
12 ms
6ms
Service Manual 31
Operation