hit counter script
Table of Contents

Advertisement

Wrap the insulation material around the connect-
ing portion.
1. Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there may be no
gap.
2. Wrap the area which accommodates the rear piping
housing section with vinyl tape.
3. Bundle the piping and drain hose together by wrap-
ping them with cloth tape over the range within
which they fit into the rear piping housing section.
Reroute the pipings and the drain hose across the
back of the chassis.
Indoor unit installation
1. Remove the spacer.
2. Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
3. Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).
Plastic bands Insulation material
Connection
pipe
Vinyl tape
Wrap with vinyl tape
(wide)
Pipe
Vinyl tape(narrow)
Connecting cable
Pipe
Drain hose
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
Piping for
passage through
piping hole
Service Manual 19
Installation
Indoor
unit piping
Connecting
cable
Drain hose

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents