Installation
1. Installation of indoor, Outdoor unit
1) Selection of the best location
1. Indoor unit.
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles to prevent the air
circulation.
• A place where air circulation in the room will be
good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consid-
eration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
2. Outdoor unit.
• If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat radia-
tion from the condenser is not restricted.
• There should not be any animals or plants which
could affected by hot air discharged.
• Ensure the spaces indicated by arrows from the
wall, ceiling, fence, or other obstacles.
3. Piping length and the elevation.
Pipe size
GAS LIQUID
LS-P0760CL/P0760HL
LS-P0820CL
3/8"
LS-P0960CL/P0960HL
LS-S0960CL/S0960HL
LS-S1120CL
1/2"
LS-S1260CL/S1260HL
LS-S1420CL/S1421CL
Max. piping
Max.
length
elevation
A(m)
B(m)
1/4"
7
5
1/4"
7
5
Ringt
Rear right
More than
5cm
More than eye-level
More than
10cm
More than
70cm
Indoor unit
ƒ¡22ƒ¡
Front
Down right
Rear left
More than 5cm
More than
10cm
A
B
Outdoor unit
left
More than
5cm