4. Redundancy setting method

4.1 Configuring the settings with two LED controllers connected to the PC using LAN cables
Connect the LED controllers and the LED modules with LAN cables.
Terminate the Backup system connection at the RJ-45 connector located top left on the last module in the
daisy chain connection.
HUB
LED controllers
Main (Primary)
Backup
* For the MCTRL 4K LED controller, the way to make connections is similar to this example.
Start the control software NovaLCT and log in with the administrator privileges.
Display the login screen as follows: User(U) -> Advanced Synchronous System UserLogin(A). Enter the
password ("admin") to log in with the administrator privileges.
Click "Screen Configuration".
LED-FE/FC
LED-E