WIRING CONNECTION
10
Connecting cables between indoor unit and outdoor unit
Outdoor
unit
3
2
1
CAUTION
!
The power cable connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4
(This equipment shall be provided with a cable set complying with the national regulation.
10±3 mm
For the 1-Phase
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cable set complying with the national
regulation.)
10±3 mm
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
If the supply cable is damaged, it must be replaced by a special cable or assembly availible
from the manufacturer of its service agent.
Indoor
unit
3
2
1
Model
APUW36GT3S1
When the connection line between the indoor unit and out-
door unit is over 40 m, connect the telecommunication line
and power line separately.
2
2
Phase(Ø)
Area(mm
) Cable Type
1
2.5
H07RN-F