,,_CAUTION ,_
Ifa power plug is not to be used, provide a circuit breaker between power source and the
unit as shown below.
Main power source
I
Air
Cond t onerJ
L_ CircUituse
a circuitBreaker
Model
Power s ource FUSecapacityOr
breaker
breaker or time
18K
1_,230/208V
15A
delay fuse.
24K
1e,230/208V
20A
Connectthe cable to the indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
• Ensure that the color of the wires of outdoor unit
and the terminal No. are the same as those of
indoor unit respectively.
(Refer to Wiring diagram on page11.)
• Be sure to refer to the wiring diagram label inside
the cover control and carry out the correct field
wiring.
Wrong wiring can cause the unit to misoperate to
result in a fire hazard.
• Check local electrical codes and any specified
wiring instructions or limitations.
Connecting
cable
2. Attach the Grille onto the cabinet.
• Grasp lower the left and right side of the Grille
and engage four tabs on the top insideedge of
the chassis.
• Press the Grille toward the chassis until it will be
back into place.
/